
Tab.3
Heating mode: outside air tempe7 °C, water temperature at the 35 °C. Performances in accordance
with EN 14511-2.
Measure
ment type
Unit
AWHP 4.5
MR
AWHP 6
MR-3
AWHP 8
MR-2
AWHP 11
MR-2
AWHP 11
TR-2
AWHP 16
MR-2
AWHP 16
TR-2
Heat output kW
4.60
5.79
8.26
11.39
11.39
14.65
14.65
Coefficient
of Perform
ance (COP)
5.11
4.05
4.27
4.65
4.65
4.22
4.22
Absorbed
electrical
power
kWe
0.90
1.43
1.93
2.45
2.45
3.47
3.47
Nominal wa
ter flow rate
(ΔT = 5 K)
m
3
/hour
0.88
1.13
1.53
1.96
1.96
2.53
2.53
Tab.4
Heating mode: outside air tempe2 °C, water temperature at the 35 °C. Performances in accordance
with EN 14511-2.
Measure
ment type
Unit
AWHP 4.5
MR
AWHP 6
MR-3
AWHP 8
MR-2
AWHP 11
MR-2
AWHP 11
TR-2
AWHP 16
MR-2
AWHP 16
TR-2
Heat output kW
3.47
3.65
5.3
10.19
10.19
12.90
12.90
Coefficient
of Perform
ance (COP)
3.97
3.23
3.46
3.20
3.20
3.27
3.27
Absorbed
electrical
power
kWe
0.88
1.13
1.53
3.19
3.19
3.94
3.94
Tab.5
Cooling mode: outside air tempe35 °C, water temperature at the 18 °C. Performances in accordance
with EN 14511-2.
Measure
ment type
Unit
AWHP 4.5
MR
AWHP 6
MR-3
AWHP 8
MR-2
AWHP 11
MR-2
AWHP 11
TR-2
AWHP 16
MR-2
AWHP 16
TR-2
Cooling out
put
kW
3.80
4.69
7.90
11.16
11.16
14.46
14.46
Energy effi
ciency ratio
(EER)
4.28
4.09
3.99
4.75
4.75
3.96
3.96
Absorbed
electrical
power
kWe
0.89
1.15
2.00
2.35
2.35
3.65
3.65
Tab.6
Common specifications
Measure
ment type
Unit
AWHP 4.5
MR
AWHP 6
MR-3
AWHP 8
MR-2
AWHP 11
MR-2
AWHP 11
TR-2
AWHP 16
MR-2
AWHP 16
TR-2
Power sup
ply voltage
of the out
door unit
V
230
230
230
230
400
230
400
Start-up
amperage
A
5
5
5
5
3
6
3
Maximal
amperage
A
12
13
17
29.5
13
29.5
13
Refrigerant
fluid R410A
kg
1.3
1.4
3.2
4.6
4.6
4.6
4.6
R410A re
frigerant
tCO
2
e
2.714
2.923
6.680
9.603
9.603
9.603
9.603
3 Technical specifications
7706698 - v04 - 17102018
AWHP-2 PBS-i
11