5.1.1
Connect and configure the SYSMGR PBS heat pump
with electrical back-up with a domestic hot water tank
and a direct circuit
Fig.17
MW-5000766-3
230V ou 400V
50Hz
2
3
0
V
5
0
H
z
M
AB
A
4
2
5
3
X23
X12
X28
1
3
8
5
X25
4
1
8
2
B
EHC-04
1 Outdoor temperature sensor
2 Wiring kit for direct underfloor heating
3 Mago connected thermostat
4 Heating/domestic hot water reversal valve
5 Domestic hot water sensor
8 Outdoor unit bus connection
1. Connect the accessories and options to the EHC–04 PCB, respecting
the 230-400 V and 0-40 V cable feed-throughs.
2. On initial start-up, or after a reset of the factory parameters, set the
CN1 and CN2 parameters according to the output of the outdoor unit.
3. Select the number corresponding to the installation type by pressing
the or key.
Installation type
No.
1 direct underfloor h 1 domestic hot water tank
06
Selecting the installation type enables automatic configuration of the
parameters required for the control panel to operate correctly
(gradient, maximum circuit temperature, etc.).
4. Confirm the selection by pressing the
key.
The main parameters are set.
5 Connecting diagrams and configuration
26
AWHP-2 PBS-i
7706696 - v04 - 11102018