3.3.5
SYSMGR PBS with hydraulic back-up
Fig.8
MW-3000532-01
6
7
9
6
2
1
63
65
65
65
55 55
16
400
218
45
40
1
2
3
4
5
6
402
56,5
1 Heating circuit flow G 1"
2 Heating circuit return G 1"
3 Back-up boiler flow G 1"
4 Back-up boiler return G 1"
5 5/8" refrigerant gas connection
6 3/8" refrigerant fluid connection
Fig.9
Insulated version
MW-3000533-01
55
32
22
2
1
3
63
65
63
65
4
3
2
1
5
6
57
211
48
1 Heating circuit flow G 1"
2 Heating circuit return G 1"
3 Back-up boiler flow G 1"
4 Back-up boiler return G 1"
5 5/8" refrigerant gas connection
6 3/8" refrigerant fluid connection
3 Technical specifications
7706696 - v04 - 11102018
AWHP-2 PBS-i
19