Operation manual for
BAUER RAINSTAR
Series T32, T42
41
CONSTANTS
Konst.
Nr.
Anm. Werks
einstel
lung
Min.
value
Max.
value
Description
0
100
-
- 111 code for reaching the machine data
1
00:00
00:00
24:00
Time
2 8 1
15
Pre-irrigation
3 8 1
15
Post-irrigation
4
20
0
99 Monitoring time [Minutes]
0 = without shut-off valve , 20 = with shut-off valve
5
1
1
15 1 English, 2 Danish, 3 German, 4 French, 5 Dutch,
6 Schwedish 7 Spanish, 8 Italian, 9 Polish, 10 Japanese
6
0
0
2 0 = slow shut-off, for option shut-off valve-over pressure
1 = fast switch off, for option shut-off valve low-pressure (shut-off valve
opens and closes again after 3 minutes)
2 = without option shut-off valve
7
-
0
1000 input of the laid down pipe [m]
8
0
0
1000 Early stop [m]
(* is carried out when post-irrigation has been selected*)
9
0
0
1000 Distance to post-irrigation [m]
10
0
0
1000 input PE-pipe length for alarm [m]
11
40
5
120 Amount of water [m3/h]
12
60
5
100 Distance between irrigation width [m]
The constant No. 0 (Code) must be set to 111 to get access to the machine data.
When pressing the key „PROG“-you get the machine data are shown.
If the water amount (according to performance chart) constant 11 and the
distance between the irrigation tracks (strip width according to performance
chart)
constant 12 is not entered the dose indicated on the display is not correct.
ATTENTION!