CABLE CONNECTIONS –CONNECTION DIAGRAM
ECOSTAR 4300 18-Pol-Stecker
Cable connection. Version n.n1
1 + Battery
brown
12 V
2 - Battey blue
3 + Solar panel blue
4 - Solar panel
blue
5 Motor 1
regulating motor
6 Motor 1
regulating motor
7 Speed sensor 1 * blue
8 Speed sensor 1 * black
9 Speed sensor 2 * yellow/green
10 Speed sensor 2 * brown
11 Stop sensor
blue or brown
12 Stop sensor
blue or brown
13 Motor 2
shut-off motor
14 Motor 2
shut-off motor
15 Pressure sensor blue or brown
16 Pressure sensor
blue or brown
17 - BIP
18 + BIP
Cable connections for SMS
19 + Battery
bown
+12 V
20 - Battery
blue
21 Not occupied
22 Not occupied
23 Not occupied
24 Not occupied
* if the distance counter counts into the wrong direction the
speed sensor must be turned around.
Attention: Power for modem only available if machine
constant 30 is on 1 or 2 !!!
ATTENTION!