Fittings with parallel threads (O-ring seal type)
The tightening torques for fittings with parallel threads (O-ring seal method) are shown in the table
below.
Tightening an adjustable joint forcibly with a spanner or other such tool to secure it to a set position
could damage the adjustable joint, its washers, and other parts. Be sure to tighten an adjustable
joint to the torque appropriate to its size.
Nominal diameter
of thread
Tightening torque
N-m
kgf-cm
lb-in.
1/4
34.32 - 49.03
350 - 500
309.79 - 442.55
3/8
68.65 - 78.45
700 - 800
619.57 - 708.08
1/2
98.07 - 117.68
1000 - 1200
885.10 - 1,062.12
3/4
147.10 - 176.52
1500 - 1800
1,327.65 - 1,593.18
1
245.17 - 274.59
2500 - 2800
2,212.75 - 2,478.28
1-1/4
294.20
3000
2,655.30
1-1/2
294.20
3000
2,655.30
2
392.27
4000
3,540.40