11. Image control via DMX
11. IMAGE CONTROL VIA DMX
11.1 Introduction
Overview
The projected image can be controlled via DMX using channels 16 to 51.
The following functions are available
•
Source selection
•
Brightness
•
Contrast
•
Orientation
•
Blanking
•
Soft edge
•
Warping
11.2 Source selection
Channel 16
Value
Default Action
0 - 31
0
No source selected, default white image displayed
32 - 63
RGBHW selected
64 - 95
HD-SDI/SDI selected
96 - 127
DVI selected
128 - 159
Media player selected
160 - 191
No source selected / for future expansion
192 - 223
No source selected / for future expansion
224 - 255
No source selected / for future expansion
11.3 Brightness - Contrast - Saturation
Overview
Channel 17 adjusts the brightness between 0 and 100% when sending a value between 0 and 255.
Channel 18 adjusts the contrast between 0 and 100% when sending a value between 0 and 255.
Channel 19 adjusts the saturation between 0 and 100% when sending a value between 0 and 255.
11.4 Orientation
Channel 20
Value
Default Action
0 - 31
0
Normal
32 - 63
Mirror
64 - 95
Flip
96 -127
Flip + Mirror
128 - 255
For future expansion
R59770208 DML-1200 06/11/2009
63
Summary of Contents for DML-1200
Page 1: ...DML 1200 User guide R9050120 R59770208 04 06 11 2009...
Page 12: ...1 Safety 8 R59770208 DML 1200 06 11 2009...
Page 30: ...4 Connections 26 R59770208 DML 1200 06 11 2009...
Page 32: ...5 Start up of the Adjustment mode 28 R59770208 DML 1200 06 11 2009...
Page 37: ...6 Input menu Image 6 18 Image 6 19 Image 6 20 R59770208 DML 1200 06 11 2009 33...
Page 38: ...6 Input menu 34 R59770208 DML 1200 06 11 2009...
Page 52: ...8 Control menu 48 R59770208 DML 1200 06 11 2009...
Page 62: ...9 Service menu 58 R59770208 DML 1200 06 11 2009...
Page 66: ...10 Moving light control via DMX 62 R59770208 DML 1200 06 11 2009...
Page 76: ...12 Maintenance 72 R59770208 DML 1200 06 11 2009...
Page 98: ...A DMX chart 94 R59770208 DML 1200 06 11 2009...
Page 104: ...C Troubleshooting 100 R59770208 DML 1200 06 11 2009...
Page 106: ...D Specifications 102 R59770208 DML 1200 06 11 2009...
Page 108: ...E Order info 104 R59770208 DML 1200 06 11 2009...