4. Connections
Networking tips & tricks
•
Use high quality network equipment
•
Use CAT 5e or CAT 6 UTP cables
•
Unless
fi
tted by a professional network installer, do not use handmade cables. If handmade cables are used, make sure they
are made with proper tools and are tested on performance.
•
For UTP cabling, limit the length of the cables to 50 meter. If a bigger distance needs to be covered, it’s adviced to use
fi
ber
optics or repeaters (hubs).
•
Do not pull the cables with brute force
•
Do not run cables along with or close to electric cabling
•
Avoid sharp bends in the cabling
•
If possible, separate the network with the DMLs from any corporate or public network to avoid performance loss, contamination
(virus risk), and security breaches.
•
It is advised to put all DMLs on the same network range (both embedded controller and EMP). This makes the network easier
to use and understand, and all components will be reachable for the Projector Toolset
For complex and large network setups, we advice to contact a professional network specialist and installer.
USB port
The communication interface is equipped with two USB ports, type “A” connectors (E). These USB ports are use by service techni-
cians to connect a keyboard and mouse to the available media player or another USB device.
VGA out
To connect a monitor to the available media player. This VGA out is used in combination with the USB ports to control the media
player for service purposes.
LED indications
The LED indication next to the jog dial have the following function:
Yellow LEDs LMP1, LMP2, LMP3, LMP4 : On when the corresponding lamp is on. Off when the corresponding lamp is off.
Indica-
tion
Color
Description
LMP1
Yellow
ON : when lamp 1 is on
ON - OFF (blinking): lamp 1 is in after cooling.
OFF : when lamp 1 is not ignited.
LMP2
Yellow
ON : when lamp 2 is on
ON - OFF (blinking): lamp 2 is in after cooling.
OFF : when lamp 2 is not ignited.
LMP3
Yellow
ON : when lamp 3 is on
ON - OFF (blinking): lamp 3 is in after cooling.
OFF : when lamp 3 is not ignited.
LMP4
Yellow
ON : when lamp 4 is on
ON - OFF (blinking): lamp 4 is in after cooling.
OFF : when lamp 4 is not ignited.
DMX
Green
ON - OFF (blinking): when the device received DMX data within the last 3 seconds.
OFF : no DMX data received.
MP
Green
ON : when the Media Player is on
ON - OFF (blinking): when the Media Player software is up and running
OFF : when Media Player is off
ON
Green
ON : when the head is on
ON - OFF (blinking): when the head is on and ready
OFF : head is not ready
ERR
Red
ON : indicates a warning in the head during operation. A warning allows normal operation, but some
hardware in the device does not match the required speci
fi
cations
ON - OFF (blinking): indicates a fatal error. Service is required.
OFF : no errors detected
R59770208 DML-1200 06/11/2009
23
Summary of Contents for DML-1200
Page 1: ...DML 1200 User guide R9050120 R59770208 04 06 11 2009...
Page 12: ...1 Safety 8 R59770208 DML 1200 06 11 2009...
Page 30: ...4 Connections 26 R59770208 DML 1200 06 11 2009...
Page 32: ...5 Start up of the Adjustment mode 28 R59770208 DML 1200 06 11 2009...
Page 37: ...6 Input menu Image 6 18 Image 6 19 Image 6 20 R59770208 DML 1200 06 11 2009 33...
Page 38: ...6 Input menu 34 R59770208 DML 1200 06 11 2009...
Page 52: ...8 Control menu 48 R59770208 DML 1200 06 11 2009...
Page 62: ...9 Service menu 58 R59770208 DML 1200 06 11 2009...
Page 66: ...10 Moving light control via DMX 62 R59770208 DML 1200 06 11 2009...
Page 76: ...12 Maintenance 72 R59770208 DML 1200 06 11 2009...
Page 98: ...A DMX chart 94 R59770208 DML 1200 06 11 2009...
Page 104: ...C Troubleshooting 100 R59770208 DML 1200 06 11 2009...
Page 106: ...D Specifications 102 R59770208 DML 1200 06 11 2009...
Page 108: ...E Order info 104 R59770208 DML 1200 06 11 2009...