May 22, 2023
EZ-SCREEN SLS Safety Light Curtain Instruction Manual
48
5-pin
male M12
+24 V DC
0 V DC
1 - brown
5 - green/
yellow
3 - blue
4 - black
2 - white
Jumper or
open to test
XS/SC26-2xx
XS2so or XS4so
+24VDC
+24VDC 0VDC
0VDC
SO1a
(SO1 not split)
SO1b
EDM
FSD1
FSD2
Single-Channel
Safety Stop Circuit
Dual-Channel
Safety Stop Circuit
1 - Brown
6 - Blue
5 - Black
4 - White
3 - Orange
2 - Orange/Black
+24 V DC
Scan Code **
Ground
0 V DC
OSSD1
OSSD2
EDM
Fault Output ***
8-pin male
M12
IN1
IN2
DEE8-..D Adapter Cordsets can be used in a similar manner as the QDE-8..D.
EZ-SCREEN receiver DIP switches are configured for “Trip” (T) output and 1-channel EDM (E1). If the Auxiliary output is not
desired, configure the EZ-SCREEN receiver for 2-channel EDM (E2) and connect pin #3 (Or) to pin #2 (or/bk).
Emitter (with Test)—Generic Wiring
Figure 24.
Self-checking Safety Module, Safety Controller, Safety PLC (no monitoring, no reset)—Generic Receiver
Wiring
Figure 25.