May 22, 2023
EZ-SCREEN SLS Safety Light Curtain Instruction Manual
55
•
•
•
•
•
It is important to snap close the cover to maintain the sensors’ IP65 environmental rating. If an access cover is lost or dam-
aged, order a replacement from the factory (see
). For installations subject to shock and vi-
bration, always reinstall the security plate.
To invert the display, use a push button located under the access cover. Invert the display when an emitter and receiver are
mounted with the QD connector ends up. Replacement access covers with inverted labels can be requested from Banner En-
gineering to accommodate inverted mounting (see
The setting for Trip or Latch Output determines whether the System will enter RUN mode automatically after power-up, or if it
will require a manual reset first. If the System is set for Trip Output, other measures must be taken to prevent a pass-through
hazard.
If Trip Output is selected, the OSSD outputs will turn ON after power is applied and the receiver passes its internal
self-test/synchronization and recognizes that all beams are clear. The OSSD outputs will also turn on after all beams
are cleared following a blocked beam.
If Latch Output is selected, the
EZ-SCREEN SLS
requires a manual reset for the OSSD outputs to turn ON, whenev-
er power is applied and all beams are clear, or following a blocked beam.
WARNING:
Use of automatic (trip) or manual (latch) start/restart
Failure to follow these instructions could result in a serious injury or death.
Applying power to the
Banner Engineering Corp.
device, clearing the defined area, or resetting a
latch condition must not initiate dangerous machine motion. Design the machine control circuitry
so that one or more initiation devices must be engaged to start the machine (a conscious act), in
addition to the
Banner Engineering Corp.
device going into Run mode.
System resets are performed using an external reset switch. This switch must be located outside the guarded area, and must
not be within reach from within the guarded area (see
"Reset Switch Location" on page 25
). Its location should provide a
clear view of the entire safeguarded area. If any hazardous areas are not in view from the switch location, additional means
Using a small, flat-bladed screwdriver or the security plate tool, push the plastic tab on the access cover inwards at a
45° angle.
2.
Pivot the screwdriver against the bevel until the access cover pops open.
3.
Make your changes to the DIP switch settings.
4.
To close the access cover, push the cover into place until it "snaps" into place. The access cover has been designed
to be removable, so if it should come off, snap it back onto the hinge and close it.
5.
Replace the security plate with the tamper-resistant screws provided, using the security plate tool.
6.
Inverted Display
6.2.2
Selectable Trip/Latch Outputs
6.2.3
Reset Procedures
6.3
© Banner Engineering Corp.
Summary of Contents for EZ-SCREEN SLS
Page 16: ...May 22 2023 EZ SCREEN SLS Safety Light Curtain Instruction Manual 16 Banner Engineering Corp...
Page 52: ...Blank page 52...
Page 68: ...Blank page 68...
Page 90: ...Blank page 90...
Page 102: ...Blank page 102...
Page 106: ...Blank page 106...
Page 114: ...LinkedIn Twitter Facebook 2023 All rights reserved www bannerengineering com...