EZ-SCREEN SLS Safety Light Curtain Instruction Manual
12
•
•
•
•
•
•
•
•
•
•
•
•
•
EZ-SCREEN SLS
is typically used for, but is not limited to, the following applications:
Small assembly equipment
Automated production equipment
Robotic work cells
Molding and power presses
Assembly and packaging machines
Lean manufacturing systems
Do not use
EZ-SCREEN SLS
in the following applications:
With any machine that cannot be stopped immediately after a stop signal is issued, such as single-stroke (or full-revo-
lution) clutched machinery
With any machine with inadequate or inconsistent machine response time and stopping performance
With any machine that ejects materials or component parts through the defined area
In any environment that is likely to adversely affect photoelectric sensing efficiency. For example, corrosive chemicals
or fluids or unusually severe levels of smoke or dust, if not controlled, may degrade sensing efficiency
As a tripping device to initiate or reinitiate machine motion (PSDI applications), unless the machine and its control
system fully comply with the relevant standard or regulation (see OSHA 29CFR1910.217, NFPA 79, ANSI B11.19, ISO
12100, IEC 60204-1, IEC 61496-1, or other appropriate standard)
is installed for use as a perimeter guard (where a pass-through hazard may exist, see
Eliminating Pass-Through Hazards
), the dangerous machine motion can be initiated by normal means only after
the safeguarded area is clear of individuals and the
EZ-SCREEN SLS
has been manually reset.
Redundancy requires that
EZ-SCREEN SLS
circuit components be backed up to the extent that, if the failure of a single com-
ponent will prevent effective machine stopping action when needed, that component must have a redundant counterpart
which will perform the same function. The
EZ-SCREEN SLS
is designed with redundant microprocessors.
Redundancy must be maintained whenever the
EZ-SCREEN SLS
is in operation. Because a redundant system is no longer
redundant after a component has failed,
EZ-SCREEN SLS
is designed to monitor itself continuously. A component failure de-
tected by or within the self-checking system causes a stop signal to be sent to the guarded machine and puts the
EZ-
SCREEN SLS
into a Lockout condition.
A recovery from this type of Lockout condition requires:
Replacement of the failed component (to restore redundancy)
The appropriate reset procedure
The Diagnostic Display is used to diagnose causes of a Lockout condition. See
Short Circuit Protection
All inputs and outputs are protected from short circuits to +24
V DC or DC common
Electrical Safety Class
III (per IEC 61140)
Safety Rating
Type 4 per IEC 61496-1, -2
Category 4 PL e per EN ISO13849-1
SIL3 per IEC 61508; SIL CL3 per IEC 62061
PFHd: 4.3 × 10
-9
Examples: Appropriate Applications
3.4.1
Examples: Inappropriate Applications
3.4.2
Control Reliability: Redundancy and Self-Checking
3.5
Specifications
3.6
General Specifications
3.6.1
© Banner Engineering Corp.
Summary of Contents for EZ-SCREEN SLS
Page 16: ...May 22 2023 EZ SCREEN SLS Safety Light Curtain Instruction Manual 16 Banner Engineering Corp...
Page 52: ...Blank page 52...
Page 68: ...Blank page 68...
Page 90: ...Blank page 90...
Page 102: ...Blank page 102...
Page 106: ...Blank page 106...
Page 114: ...LinkedIn Twitter Facebook 2023 All rights reserved www bannerengineering com...