NOTE
: In coffin garages (those with no access other
than the garage door), the lock handle should be
installed immediately after fitting the lock panel.
The lock handle is to be fixed to the middle of the
second panel. Using lock plate as a guide, centre on
central end stile and drill through the end stile and the
panel using a 1/2” (13 mm) drill bit for the large hole
and a 3/16”(5 mm) bit for the two holes on either side.
Fit the “T” handle to the panel by inserting the lock
shaft and the two 3/16” thread bolts into the panel
from the outside, through the lock muntin. Attach
the 3/16” or 4.7 mm nuts and washers securing the
‘T’ Handle in place. Next insert the lock guide plate
(dimples facing away from door) followed by the
internal handle, the lock cam and the second guide
plate (dimples facing the door). Lock together with
3/16” nuts and washers, see Figure 3.1.2.
Lock Strikes
External Lock
Handle
Internal Lock
Handle
Lock Cam
Lock Guide Plates
Lock Cable
Washer
Nuts
Lock Catch
FIGURE 3.1.1 PARTS
FIGURE 3.1.2 LOCK ASSEMBLY
External Lock Handle
Lock Guide Plate
Internal Lock Handle
Lock Cam
Lock Washer
Nut 4mm
Lock Guide Plate
3.0 OPTIONAL COMPONENTS
3.1 LOCK INSTALLATION (PFT & PFI ONLY)
NOT SUITABLE FOR
B&D STORM-SHIELD
™
29
panelift
®
pFT, panelift
®
Icon
™
pFI, b&D Storm-Shield
™
pFI and Insul-Shield
™
Installation Instructions
Revision 9 - March 2016