2.4 FITTING PFT & PFI REINFORCING
Doors wider than 3545mm require panel reinforcing, the
number and positioning of the reinforcing is shown on page 7.
Some pFT & pFI doors and all b&D Storm-Shield
™
pFI doors
are supplied with double end stiles and extended wheels,
Figure 2.4.1.
FIGURE 2.4.1
DOUBLE ENDSTILE
DOOR
REINFORCEMENT PLACEMENT
The reinforcement is generally fixed across the centre of
the panel. However there are three situations that require
alternative placement. The top panel with automatic opener,
the top panel with windows, the locking panel when a lock is to
be installed.
If a lock is to be fitted it generally straddles the centre of the
panel so the reinforcement has to be offset to allow clearance
for the installation and operation of the lock.
Fit the top panel reinforcing as high as possible when windows
and automatic openers are fitted (refer detail below).
It is important to secure reinforcing with 2 screws per stile.
FIGURE 2.4.2
REINFORCING WITH
SAFETY END CAPS FITTED
Hinge Pin
Hinge Link
Extended Wheel Axle
FIGURE 2.4.3
REINFORCING INSTALLED
ON THE TOP PANEL OF
THE DOOR
FIGURE 2.4.4 ASSEMBLE LINKS
& PINS ONTO THE PANEL
Insert the polyethylene hinge links into the recesses at the
top of the panel and fix into place using the white pins, insert
appropriate wheels and axles, Figure 2.4.4.
14
panelift
®
pFT, panelift
®
Icon
™
pFI, b&D Storm-Shield
™
pFI and Insul-Shield
™
Installation Instructions