Assemble the track as shown in Figure 2.10.1, ensure that the plastic curve is aligned and butts up against the vertical track and
horizontal track snugly.
The horizontal tracks are identified by being the longer pair of tracks supplied and should be at least:
Door 350mm
2.10 INSTALLING HORIzONTAL TRACKS
The safety stops must always be fitted
at the end of the horizontal track to
prevent the panels from accidently
exiting track.
INSTALLING THE
SAFETY STOP
Track
Stop
The safety pull cord must always
be fitted to the door. pass the cord
through the white hinge pin, adjust
length and tie in a knot at each end.
Alternatively fit ‘D’ handle.
INSTALLING THE SAFETY
PULL CORD OR ‘D’ HANDLE
Pull Cord
FIGURE 2.10.1 ASSEMBLING HORIZONTAL TRACK
EQUAL
EQUA
L
Ensure a washer is
used under the wiz nut
FIGURE 2.10.2 BRACING
Fix to
Ceiling
Horizontal Track
Angle
¾ Door Height
FIGURE 2.10.3
SINGLE BRACE
Ensure a washer is
used under the wiz nut
19
panelift
®
pFT, panelift
®
Icon
™
pFI, b&D Storm-Shield
™
pFI and Insul-Shield
™
Installation Instructions
Revision 9 - March 2016