background image

Via Mantova, 177/A - 37053 Cerea (Verona) Italy - Tel. +39 0442 330422 r.a. - Fax +39 0442 331054 - e-mail: [email protected] - www.fadini.net

®

INSTALLATION MANUAL

The manufacturers reserve the right to change the products without any previous
notice and are not liable for possible damages to people and properties.

Distributor’s box

The growth of MECCANICA FADINI has always been based on the
development of guaranteed products thanks to our “TOTAL QUALITY
CONTROL” system which ensures constant quality standards,
updated knowledge of the European Standards and compliance
with their requirements, in view of an ever increasing process of
improvement.

EUROPEAN MARK CERTIFYING CONFORMITY TO
THE ESSENTIAL REQUIREMENTS OF THE
STANDARDS 98/37/EC

• DECLARATION OF CONFORMITY
• GENERAL WARNINGS
• EN 12453, EN 12445 STANDARDS
• CEI EN 60204-1 STANDARDS
• WARRANTY CERTIFICATE

155

150

150

150

38

356

40

40

344

136

324

160

116

10

10

12

156

156

460

140

50

65

165

230

230

230

460

OIL-HYDRAULIC JACK

Rotation angle ............................................................110

°

/175

°

Rotation time 110

°

...............................................................23 s

Rotation time 175

°

...............................................................28 s

Max. rated torque ..........................................................235Nm
Piston diametre ................................................................75mm
Piston stroke.....................................................................52mm
Working temperature.........................................-20

°

C - +80

°

C

Oil volume.......................................................................0,25dm

3

Static gate weight  ..........................................................700Kg

PERFORMANCE

Duty cycle: ............23 s Opening - 30 s Dwell - 23 s Closing
Time of one complete cycle:...............................................76s
No. of complete cycles Opening-Stop-Closing .......47/Hour
137

.

000 cycles per year, 8 hours’ service per day

CHECKING AND MAINTENANCE:

To achieve an optimum performance and longer life of the equipment and in observance of the safety regulations, it is
recommended that inspections and proper maintenance are made by qualified technicians to the whole installation ie, both
the mechanical and electronic parts, as well as wiring:
- Mechanical parts: maintenance every 6 months approx.
- Eletronic apparatus and safety equipment: maintenance every month.

110

°

 DRIVE 700 OVERALL DIMENSIONS

TECHNICAL SPECIFICATIONS

ELECTRIC MOTOR

Power Yield...................................................................0.24KW (0.33HP)
Supply voltage...................................................................................230V
Frequency ..........................................................................................50Hz
Absorbed current .................................................................................2A
Absorbed power.............................................................................400 W
Capacitor........................................................................................12.5 

µ

F

Motor rotation speed............................................................1

.

350 r.p.m.

Intermittent service............................................................................. S3

OIL-HYDRAULIC MOTOR/PUMP UNIT

Pump flow rate P3................................................................0.85 

l

/1 min.

Average working pressure............................................1MPa (10bars)
Max. pump pressure.......................................................3MPa (30bars)
Oil type ...........................................................OIL FADINI A 15 BY AGIP
Tank capacity ..............................................................................0.95 dm

3

Static weight ......................................................................................8 Kg
Working temperature .......................................................-20

°

C - +80

°

C

Protection standards .....................................................................IP 673

AUTOMATIC GATE MANUFACTURERS

®

s.n.c.

Made in Italy

®

GB

9-2004

Summary of Contents for DRIVE 700

Page 1: ...stroke 52mm Working temperature 20 C 80 C Oil volume 0 25dm3 Static gate weight 700Kg PERFORMANCE Duty cycle 23 s Opening 30 s Dwell 23 s Closing Time of one complete cycle 76s No of complete cycles O...

Page 2: ...stem PIC 2 DRIVE 700 PIC 1 GATE STOP IN OPEN GATE POSITION ENCLOSURE GUIDE BASE PLATE FIXING ANGLES FIXING BASE PLATE ENCLOSURE LID NERROW SECTION ENCLOSURE LID LARGE SECTION MOTOR PUMP UNIT MOTOR PUM...

Page 3: ...stem PIC 2 DRIVE 700 PIC 1 GATE STOP IN OPEN GATE POSITION ENCLOSURE GUIDE BASE PLATE FIXING ANGLES FIXING BASE PLATE ENCLOSURE LID NERROW SECTION ENCLOSURE LID LARGE SECTION MOTOR PUMP UNIT MOTOR PUM...

Page 4: ...position and the setting is maintained for long time By means of a wrench rotate the jack shaft until you can feel that the limit of the permitted stroke in closed gate position is reached in this po...

Page 5: ...position and the setting is maintained for long time By means of a wrench rotate the jack shaft until you can feel that the limit of the permitted stroke in closed gate position is reached in this po...

Page 6: ...as the photocells keyswitch etc FITTING THE ELECTRIC LOCK THE MECHANICAL LATCHING BOLT AND THE GATE STOPS It is recommended to fit the gates with an electric lock either vertically or horizontally pos...

Page 7: ...as the photocells keyswitch etc FITTING THE ELECTRIC LOCK THE MECHANICAL LATCHING BOLT AND THE GATE STOPS It is recommended to fit the gates with an electric lock either vertically or horizontally pos...

Page 8: ...if mounted outside a suitable enclosure is recommended to protect it from sunshine and rain 2 Bridge terminals 1 2 if you do not require any photocells 3 Should two sets of photocells be required thes...

Page 9: ...if mounted outside a suitable enclosure is recommended to protect it from sunshine and rain 2 Bridge terminals 1 2 if you do not require any photocells 3 Should two sets of photocells be required thes...

Page 10: ...ulic motor pump units both gates are to be operated in the same direction Should they fail to perform in a synchronized way swap the electrical motor connections ie live 1 and 2 for both gates to open...

Page 11: ...ulic motor pump units both gates are to be operated in the same direction Should they fail to perform in a synchronized way swap the electrical motor connections ie live 1 and 2 for both gates to open...

Page 12: ...stroke 52mm Working temperature 20 C 80 C Oil volume 0 25dm3 Static gate weight 700Kg PERFORMANCE Duty cycle 23 s Opening 30 s Dwell 23 s Closing Time of one complete cycle 76s No of complete cycles O...

Reviews: