7
6
PIC. 12
PIC. 14
- Fix the
electro-hydraulic motor pump unit
by means of expanding
bolts (not included). It is to be fixed close to the gate to operate
in the most suitable position considering all the fitting, setting and
testing operations involved.
- Excavate between the
jack
and the
motor pump
(Pic.12) and lay
a tube to house the pipes: copper pipes are supplied on request
in one length to be bent on site to meet the application requirements.
- Assemble the
enclosure
around the
jack
and fix it with concrete.
Fill in the whole escavation from the hole where the
jack
is located
to the
motor pump unit
where the pipes are laid.
FILLING THE MOTOR PUMP WITH POWER OIL
- Unlock the
motor pump front cover
by the provided key and remove
it. Incorporated in the
motor pump unit
is a
funnel
. Pull it outwards
(2 cm approx.) and turn it up (Pic. 13).
- The power oil, supplied with the equipment in a 3
l
container, is to
be poured up to the sight glass.
HYDRAULIC
MOTOR
PUMP UNIT
HYDRAULIC
JACK
FIXING
BOLTS
OIL-HYDRAULIC
JACK
PIPE CONDUIT
ENCLOSURE
GRAVEL LAYER TO
PROVIDE A SOAKAWAY
FRONT COVER
HYDRAULIC
MOTOR PUMP
UNIT
HYDRAULIC
JACK
HYDRAULIC
MOTOR PUMP
UNIT
PIPES
KEY
NUT
SPIGOT
3 mm
ELBOW
FITTING
PIC. 11
PIC. 13
FUNNEL
POWER SUPPLY
CABLE
IMPORTANT
: Avoid sharp bending in the pipes between the motor pump unit and the jack; make sure that all nuts in the jack and motor
pump are well tightened.
ELECTRICAL CONNECTIONS TO ELPRO 13 CEI CONTROL PANEL
Before carrying out any electrical connections read the enclosed electrical wiring diagrams (Pic.15).
IMPORTANT
: All the equipment must be properly
earthed
(Pic.15).
- The
mains, electric motor and flashing lamp
wires must have a 1.5 mm
2
square section for a max. distance of 50 m in case that a
longer distance is required, section must be 2 mm
2
.
- 1 mm
2
square section wires can be used for the
accessories
such as the
photocells, keyswitch etc.
FITTING THE ELECTRIC LOCK, THE MECHANICAL LATCHING BOLT AND THE GATE STOPS
It is recommended to fit the gates with an electric lock either vertically or horizontally positioned (70 cm high from ground level in the
second case) in order to better hold the gates in the closed position. The gate that is fitted with the electric lock is to be 5 degrees out of
phase against the other one and has to reach the stop closed position a bit later than the gate that is fitted with the catching plate. In the
case where the gate lock is horizontally fitted, it is also needed to fit a latching bolt to the gate that first reaches the gate stop. The bolt is
latched into the gate stop by the other ie. the delayed gate on approaching the gate stop (Pic.14).
IMPORTANT: Provide the installation with gate stops in the open gate position to be fixed 5
°
before the jack reaches the very end of the
permitted stroke.
FIT THE HEAD OF THE GATE THAT CLOSES FIRST WITH A LATCHING BOLT
TO BE DRIVEN INTO THE CLOSED POSITION GATE STOP WHERE A HOLE
HAS BEEN PROVIDED FIRST
GATE STOP
CLOSED POSITION
THIS GATE
CLOSES
FIRST
LATCHING BOLT
70 cm
THIS GATE
CLOSES FIRST
DELAYED
GATE
HORIZONTAL
ELECTRIC LOCK
VERTICAL ELECTRIC
LOCK
HORIZONTAL ELECTRIC
LOCK CATCHING PLATE
IIN CLOSED POSITION
70 cm
GATE STOP
OPEN
POSITION
90
°
95
°
1) MIRI 4 FLASHING LAMP
2) ELPRO 13 CEI CONTROL PANEL
3) O.O3 A MAGNETIC-THERMAL CIRCUIT
BREAKER
4) JUNCTION BOX
5) DRIVE 700 MOTOR PUMP UNIT
6) DRIVE 700 JACK
7) POLO 44 PHOTOCELL RECEIVER
8) ELECTRIC LOCK
9) POST-MOUNTED POLO 44 PHOTOCELL PROJECTOR
10)POST-MOUNTED POLO 44 PHOTOCELL RECEIVER
11)POLO 44 PHOTOCELL PROJECTOR
12) JUBI 433 EXTERNAL RADIO RECEIVER
13) BIRIO A 8 AERIAL
14) PRIT 19 KEYSWITCH
15) JUBI 433 TRANSMITTER
1
2
3
4
5
6
7
5
8
9
10
11
12
6
13
14
15
230 V
50 Hz
n
°
2x1.5
n
°
4x1
n
°
2x1
n
°
2x1
n
°
4x1
n
°
4x1.5
n
°
2x1
n
°
4x1
RG58
cable
n
°
4x1
n
°
4x1.5
n
°
4x1.5
GATE STOP IN
OPEN GATE
POSITION AT 95
°
GATE STOP IN
OPEN GATE
POSITION AT 90
°
GATE STOP IN
CLOSED GATE
POSITION
90
°
95
°
PIC. 15
OIL LEVEL