www.balluff.com
19
english
7.1
Accuracy
The specifications are typical values at DC 24 V and room
temperature, with a nominal length of 500 mm in
conjunction with the BTL-P-1013-4R, BTL-P-1013-4S or
BTL-P-1012-4R magnet or with the BTL2-S-6216-8P-Ex,
BTL2-S-5113-4K-Ex, BTL2-S-4414-4Z-Ex or
BTL2-S-4414-4Z01-Ex float.
The BTL is fully operational immediately, with full accuracy
after warm-up.
For special versions, other technical data may
apply. Special versions are indicated by the
suffix -SA on the part label.
Position resolution
1 µm
Non-linearity at
Nominal length ≤ 500 mm
Nominal length
> 500…≤ 5500 mm
Nominal length > 5500 mm
±50 µm
±0.01 % FS
±0.02 % FS
Hysteresis
≤ ±7 µm
Repeat accuracy
≤ ±5 µm
(typ. ±2.5 µm)
Temperature coefficient
1)
≤ 15 ppm/K
Ultrasonic velocity (standardized) 2850 m/s
Gradient (standardized)
8,9122807 µs/inch
Velocity detectable max.
10 m/s
7.2
Ambient conditions
Ambient temperature
–40°C…+80°C
Storage temperature
–50 °C…+85 °C
Humidity
< 90%, non-condensing
Rod pressure rating (when
installed in hydraulic cylinders)
≤ 600 bar
Shock rating
Continuous shock
per EN 60068-2-27
2), 3)
100 g/6 ms
100 g/2 ms
Vibration
per EN 60068-2-6
2), 3)
12 g, 10…2000 Hz
Degree of protection per
IEC 60529
IP68
2), 4)
7.3
Supply voltage (external)
Voltage, stabilized
10…30 V DC
Ripple
≤ 0.5 V
ss
Current draw (at 24 V DC)
≤ 120 mA
Inrush current
≤ 500 mA
Reverse polarity protection
Up to 36 V
(supply to GND)
Overvoltage protection
Up to 36 V
Dielectric strength
(GND to housing)
500 V DC
7.4
Output
Start/stop difference
Max. number of magnets
16
5)
Short-circuit protection
Signal lines to +36 V
or GND
1) Nominal length = 500 mm, magnet in the middle of the measuring range
2) Individual specifications as per Balluff factory standard
3) Resonant frequencies excluded
4) To maintain the IP68 rating, ensure that the connection at the conduit
opening also meets this standard. Thread sealant should be used on the
conduit opening to ensure protection against moisture ingress. Take
measures to prevent the possibility of internal condensation at the
conduit opening from entering the BTL.
5) Number dependent on nominal length
Ensure power is limited to ≤ 5 W!
7
Technical data
BTL7-P511-M _ _ _ _ -J-DEXC-TA12
Magnetostrictive Linear Position Sensor – Rod Style
Ignition protection “d”
Flameproof enclosure
Summary of Contents for BTL7-P511-M J-DEXC-TA12 Series
Page 2: ...www balluff com...
Page 14: ...www balluff com...
Page 38: ...www balluff com...
Page 62: ...www balluff com...
Page 86: ...www balluff com...
Page 110: ...www balluff com...
Page 134: ...www balluff com...
Page 148: ...16 5 1 1 2 3 BTL BTL 5 2 BTL BTL 5 BTL7 P511 M_ _ _ _ J DEXC TA12 d...
Page 158: ...www balluff com...
Page 172: ...16 5 1 1 2 3 BTL BTL 5 2 BTL BTL 5 BTL7 P511 M_ _ _ _ J DEXC TA12 d...
Page 181: ......