Certificate:
2411253
Project:
70099158
Master Contract:
252588
Date Issued:
2016-11-23
DQD 507 Rev. 2016-02-18
Page 4
x
Model number: As specified in the PRODUCTS section, above.
x
Electrical ratings: As specified in the PRODUCTS section, above.
x
Manufacturing date in MMYY format, or serial number, traceable to month and year of manufacture.
x
Marking on the unit that indicates the manufacturing location if the equipment is manufactured at more than
one factory location
x
Enclosure ratings: As specified in the PRODUCTS section above.
x
The CSA Mark with or without “C” and “US” indicators, as shown on the Certificate of Conformity.
x
Hazardous Location designation: As specified in the PRODUCTS section above (may be abbreviated).
x
Temperature code: As specified in the PRODUCTS section above. (optional if T5 or T6)
x
Ambient temperature rating: As specified in the PRODUCTS section above.
x
Rated maximum working pressure, as specified in the PRODUCTS section above.
x
Equipment with Zone markings shall have next to or near the CSA mark, the certificate reference in the
following form: the last two figures of the year of the certificate followed by the serial number (certificate
number of this report) of the certificate in that year followed by an “X”.
x
The following words or EQUIVALENT:
o
“Explosion Hazard. Do not connect or disconnect this equipment unless power has been removed or the
area is known to be nonhazardous” and “Risque d'explosion. Ne pas brancher ou débrancher l'appareil,
sauf si l'alimentation a été coupée ou
de la région est connue pour être non dangereux”
o
“WARNING
- OPEN CIRCUIT BEFORE REMOVING COVER and ATTENTION - OUVRIR LE
CIRCUIT AVANT D'ENLEVER LE COUVERCLE, or WARNING - KEEP COVER TIGHT WHILE
CIRCUITS ARE ALIVE and ATTENTION - GARDER LE COUVERCLE BIEN FERMÉ TANT QUE
LES CIRCUITS SONT SOUS TENSION”
o
“SEAL ALL CONDUITS WITHIN 18 INCHES” and “SCELLEZ TOUTES LES CONDUITES À 18
POUCES” and
o
Use 90°C rated conductors
An installation manual or data sheet shall be supplied with each unit, containing the following minimum marking
information:
x
Manufacturers name and address
x
Complete Electrical ratings: As specified in the PRODUCTS section, above.
x
Specification for ambient temperature rating: As specified in the PRODUCTS section, above.
x
Specification for appropriate wiring to the connector, including definition of pin functions, and specification
for wire gauge. Including the note “Use 90°C rated conductors”.
x
Mounting and installation instructions, including dimensions.
Summary of Contents for BTL7-P511-M J-DEXC-TA12 Series
Page 2: ...www balluff com...
Page 14: ...www balluff com...
Page 38: ...www balluff com...
Page 62: ...www balluff com...
Page 86: ...www balluff com...
Page 110: ...www balluff com...
Page 134: ...www balluff com...
Page 148: ...16 5 1 1 2 3 BTL BTL 5 2 BTL BTL 5 BTL7 P511 M_ _ _ _ J DEXC TA12 d...
Page 158: ...www balluff com...
Page 172: ...16 5 1 1 2 3 BTL BTL 5 2 BTL BTL 5 BTL7 P511 M_ _ _ _ J DEXC TA12 d...
Page 181: ......