Photoelectric Sensors
Laser distance sensor with IO-Link and additional functions
BOD 21M-LBI05-S4
14
english
IO-Link interface (continued)
Device-specific parameters
Index
(dec)
Name
Subindex
(dec)
Name
Data
format
Access
Value range
Remarks
0x0057
(87)
Operating
Hours
0x01 (1)
Operating
Hours
UINT32
R
Operating
hours counter
(hours)
0x02 (2)
Operating
Hours
Individual
Can be reset
using system
command
Reset
Operating
Hours
0x00B4
(180)
SIO Output
Type
0x01 (1)
Q1
UINT8
R/W
0x01 (1) = PNP
0x02 (2) = NPN
0x03 (3) = Push-Pull
In SIO Mode
0x02 (2)
Q2/Iout
0x01 (1) = PNP
0x02 (2) = NPN
0x03 (3) = Push-Pull
0x05 (5) = Analog Output
4…20 mA
0x00B5
(181)
SIO Output
Function
0x01 (1)
Unused
UINT8
R/W
0x00 (0)
In SIO Mode
0x02 (2)
Iout
0x00 (0) = Rising
Characteristics
0x01 (1) = Falling
Characteristics
0x00B6
(182)
Switch
Counter
Settings
0x01 (1)
Mode
UINT8
R/W
0x00 (0) = Off
0x01 (1) = Counter Static
0x02 (2) = Counter Auto
0x02 (2)
Limit
UINT16
0x0001…0xFFFF (1…65535)
0x03 (3)
Unused
UINT16
0
0x04 (4)
StartupDelay
UINT8
0x00…0xFF (0…255)
Seconds
0x00B7
(183)
Switch
Counter State
0x01 (1)
Status
UINT8
R
Bit 0 = Count Limit OK
Bit 1 = Count Limit Too Low
Bit 2 = Count Limit Too High
0x02 (2)
Counter
UINT16
0x00B8
(184)
Time Delay
Function Q1
(Pin 4)
0x01 (1)
Delay Function
Mode
UINT8
R/W
0x00 (0) = Delay
0x01 (1) = One shot
0x02 (2)
Delay Time 1
(On delay)
UINT16
R/W
0x0000…0xFFFF (0…65535)
0 = Timing Function off
Milliseconds
0x03 (3)
Delay Time 2
(Off delay,
One shot)
UINT16
R/W
0x0000…0xFFFF (0…65535)
0 = Timing Function off
Milliseconds
0x00B9
(185)
Time Delay
Function Q2
(Pin 2)
0x01 (1)
Delay Function
Mode
UINT8
R/W
0x00 (0) = Delay
0x01 (1) = One shot
0x02 (2)
Delay Time 1
(On delay)
UINT16
R/W
0x0000…0xFFFF (0…65535)
0 = Timing Function off
Milliseconds
0x03 (3)
Delay Time 2
(Off delay,
One shot)
UINT16
R/W
0x0000…0xFFFF (0…65535)
0 = Timing Function off
Milliseconds
0x00BA
(186)
Debounce
Time
0x01 (1)
Pin 4
UINT16
R/W
0 = Timing Function off
Debounce
time, Reset
input
(milliseconds)
0x02 (2)
Pin 2
0x0000…0xFFFF (0…65535)
0 = Timing Function off
Summary of Contents for BOD 21M-LBI05-S4
Page 1: ...deutsch Betriebsanleitung english User s guide fran ais Notice d utilisation BOD 21M LBI05 S4...
Page 2: ...www balluff com...
Page 3: ...BOD 21M LBI05 S4 Betriebsanleitung deutsch...
Page 25: ...BOD 21M LBI05 S4 User s Guide english...
Page 47: ...BOD 21M LBI05 S4 Notice d utilisation fran ais...
Page 69: ...www balluff com f r Notizen to make notes pour vos notes personelles...