Photoelectric Sensors
Laser distance sensor with IO-Link and additional functions
BOD 21M-LBI05-S4
17
english
www.balluff.com
IO-Link interface (continued)
Diagnostic parameters
Index
(dec)
Name
Subindex
(dec)
Data format
Access
Value range
Remarks
0x0024
(36)
Device
Status
0x00 (0)
UINT8
R
0x00 (0) = Device OK
0x01 (1) =
Maintenance-Required
0x02 (2) =
Out-of-Specification
0x03 (3) = Functional-Check
Not used
0x04 (4) = Failure
0x0025
(37)
Detailed
Device
Status
0x00 (0)
ArrayT of
OctetStringT3
R
Implemented as
dynamic list. See
Events with
Mode
appears/
disappears
.
0x0028
(40)
Process
Data Input
0x00 (0)
UINT40
R
See
Process
Data Output Data
0x0029
(41)
Process
Data Output
0x00 (0)
UINT8
R
See
Process
Data Input Data
Events
Event code
Meaning
Mode
Type
Device Status
Remarks
0x4210
Excess
Temperature
appears/
disappears
Warning
Out-of-Specification
0x5011
Data Loss
appears/
disappears
Error
Failure
0x5111
Undervoltage
appears/
disappears
Warning
Out-of-Specification
Supply voltage < 18 V in
IO-Link mode
0x7710
Short Circuit
appears/
disappears
Warning
Out-of-Specification
0x8CA0
Parameter
Changed
One-time
Message
OK
When parameter settings are
lost. Sensor continues to
operate using factory
defaults.
0x8DB0
Teach Timeout
One-time
Message
OK
Teach-In enabled > 10 min
0xFF91
Upload Request
One-time
Message
OK
After local parameterization
and system command
ParamDownloadStore
Summary of Contents for BOD 21M-LBI05-S4
Page 1: ...deutsch Betriebsanleitung english User s guide fran ais Notice d utilisation BOD 21M LBI05 S4...
Page 2: ...www balluff com...
Page 3: ...BOD 21M LBI05 S4 Betriebsanleitung deutsch...
Page 25: ...BOD 21M LBI05 S4 User s Guide english...
Page 47: ...BOD 21M LBI05 S4 Notice d utilisation fran ais...
Page 69: ...www balluff com f r Notizen to make notes pour vos notes personelles...