BIS M-62_ MANUAL
92
5
Common Services
Service
Code
Implementation
Service Name
Class Level
Instance Level
0x05
No
Yes
Reset*
0x0E
Yes
Yes
Get Attribute Single
0x10
No
Yes
Set Attribute Single
*This Service Code is used to flush all attributes to zero.
5.9.3 Application Object (0x67
–
10 Instances)
Class Attributes (Instance 0)
Attribute
ID
Name / Description
Data Type
Default Data
Value
Access
Rule
1
Revision
UINT
1
Get
Instance Attributes (Instances 1-32)
Attribute
ID
Name / Description
Data Type
Default Data
Value
Access
Rule
1
Instance Type
(0-3):
0 - Disable
1
– ControlLogix
2
– SLC 5/05
3
– PLC5E
USINT
0
Get
2
PLC IP Address
UDINT
0
Get
3
PLC Slot Location
(0-
255)
USINT
0
Get
11
Max Write Size
in Words:
0
– Disabled
1
– 100 Words
UINT
0
Get
12
Write Tag Name
(ControlLogix Only)
SHORT
STRING
0
Get
13
Write File Number
(SLC/PLC Only)
NX:0
- where
“X”
is the
File Number
UINT
7
Get
14
Write File Offset
(SLC/PLC Only)
N7:Y
- where
“Y”
is the
File Offset
UINT
0
Get
15
Write “Heartbeat”
Timeout
Measured in 10ms “ticks”
0 = disabled
Max value: 6000 ticks
UINT
100
Get
21
Max Read Size
in Words
0
– Disable
Max Value: 100
UINT
0
Get
22
Read Tag Name
(ControlLogix Only)
SHORT
STRING
0
Get
Summary of Contents for BIS M-370-000-A02
Page 1: ......
Page 2: ......
Page 3: ......
Page 7: ......
Page 16: ...9 BIS M 371 000 A01 BIS M 372 000 A01 BIS M 373 000 A01 BIS M 370 000 A02 Figure G...
Page 17: ...10...
Page 21: ...BIS M 62_ MANUAL 14 1...
Page 60: ...INSTALLATION 53 2...
Page 77: ...BIS M 62_ MANUAL 70 4...
Page 101: ...BIS M 62_ MANUAL 94 5...
Page 103: ...BIS M 62_ MANUAL 96 6 The HTTP Server Main Page will be displayed...
Page 126: ...DEVICENET INTERFACE 119 8...
Page 185: ...BIS M 62_ MANUAL 178 10...
Page 188: ...RFID OPERATING PRINCIPLES 181 11...