2.6.5 Installing the BIS M-622-070-A01-03-ST33
Profibus (PBS)
Figure 31 - PBS Typical Layouts
The BIS M-622-070-A01-03-ST33
Processor unit is designed for Profibus RFID applications,
where the processor unit is connected as a slave node in a Profibus (DP) network via
compatible cables directly to a Profibus Master (host).
The default Node ID is 63
.
1. Select a suitable location for the BIS M-622_ Processor unit/Antenna.
2. Mount the BIS M-37_ antenna to the BIS M-622_ Processor unit, either directly or
remotely, as described in par. 2.2.
3. Mount the processor unit and antenna to your mounting fixture using
M5 (or #10)
diameter screws (
not included
) and secure them with appropriate washers and nuts.
Tighten screws to
1.7 Nm or 15 lbs per inch ± 10%
.
4. Attach Profibus-compatible data cables to the 5-pin B-Coded (reverse-keyed), male and
female M12 interface connectors on the BIS M-622_. Connect the other end of the cables
to your Profibus network.
5. Build a power supply cable using the BCC06ZF M12 5-pin female connector. Use
minimum 24 AWG wires for connection to the power supply lines according to the Vdc
connector pinout. Connect the BCC06ZF M12 5-pin female connector to the M12 5-pin
male connector on the processor unit. Connect the other end of the cable (wires or user-
supplied connectors) to the power supply.
6. Apply power to the processor unit after all cable connections have been made. The LEDs
on the unit will flash. The READY LED is ON after the power up sequence has
completed.
to
P
ro
fib
u
s
M
a
st
e
r
B
IS
M
-6
2
2
-0
7
0
_
w a
n
te
n
n
a
PBS IN
BCC06ZF
PBS IN
PBS IN
PBS IN
PBS OUT
BCC06ZF
Profibus
Terminator
Cap
PBS OUT
PBS OUT
to Configuration PC
to Configuration PC
to Configuration PC
to Configuration
PC
to Power Supply
Summary of Contents for BIS M-370-000-A02
Page 1: ......
Page 2: ......
Page 3: ......
Page 7: ......
Page 16: ...9 BIS M 371 000 A01 BIS M 372 000 A01 BIS M 373 000 A01 BIS M 370 000 A02 Figure G...
Page 17: ...10...
Page 21: ...BIS M 62_ MANUAL 14 1...
Page 60: ...INSTALLATION 53 2...
Page 77: ...BIS M 62_ MANUAL 70 4...
Page 101: ...BIS M 62_ MANUAL 94 5...
Page 103: ...BIS M 62_ MANUAL 96 6 The HTTP Server Main Page will be displayed...
Page 126: ...DEVICENET INTERFACE 119 8...
Page 185: ...BIS M 62_ MANUAL 178 10...
Page 188: ...RFID OPERATING PRINCIPLES 181 11...