BIS M-62_ MANUAL
48
2
2.6.6 Installing the BIS M-628-075-A01-03-ST34 PROFINET (PNT)
Figure 32 - PNT Typical Layouts
The BIS M-628-075-A01-03-ST34 Processor unit is designed for PROFINET RFID
applications, where the processor unit is connected as a slave node in a PROFINET IO
network via compatible cables directly to a PROFINET Master (host).
The default IP
Address is 192.168.253.110
.
1. Select a suitable location for the BIS M-628_ Processor unit/Antenna.
2. Mount the BIS M-37_ antenna to the BIS M-628_ Processor unit, either directly or
remotely, as described in par. 2.2.
3. Mount the processor unit and antenna to your mounting fixture using
M5 (or #10)
diameter screws (
not included
) and secure them with appropriate washers and nuts.
Tighten screws to
1.7 Nm or 15 lbs per inch ± 10%
.
4. Attach PROFINET-compatible data cables to the 4-pin D-Coded, female M12 interface
connectors on the processor unit. Connect the other end of the cables to your PROFINET
network.
5. Build a power supply cable using the BCC06ZF M12 5-pin female connector. Use 18
AWG (max) to 24 AWG (min) wires for connection to the power supply lines according to
the Vdc connector pinout. Connect the BCC06ZF M12 5-pin female connector to the M12
5-pin male connector on the processor unit. Connect the other end of the cable (wires or
user-supplied connectors) to the power supply.
6. Apply power to the processor unit after all cable connections have been made. The LEDs
on the unit will flash. The READY LED is ON after the power up sequence has
completed.
B
IS
M
-6
2
8
-0
7
5
_
w a
n
te
n
n
a
to Power Supply
PNT 1
BCC06ZF
to Configuration PC
to Configuration PC
to Configuration PC
BCC06ZF
to Profinet Master
PNT 2
PNT 1
PNT 1
PNT 2
Summary of Contents for BIS M-370-000-A02
Page 1: ......
Page 2: ......
Page 3: ......
Page 7: ......
Page 16: ...9 BIS M 371 000 A01 BIS M 372 000 A01 BIS M 373 000 A01 BIS M 370 000 A02 Figure G...
Page 17: ...10...
Page 21: ...BIS M 62_ MANUAL 14 1...
Page 60: ...INSTALLATION 53 2...
Page 77: ...BIS M 62_ MANUAL 70 4...
Page 101: ...BIS M 62_ MANUAL 94 5...
Page 103: ...BIS M 62_ MANUAL 96 6 The HTTP Server Main Page will be displayed...
Page 126: ...DEVICENET INTERFACE 119 8...
Page 185: ...BIS M 62_ MANUAL 178 10...
Page 188: ...RFID OPERATING PRINCIPLES 181 11...