BIS M-62_ MANUAL
74
5
5.4 IP CONFIGURATION VIA HTTP SERVER
To configure the BIS M-626 for Ethernet communications, begin by assigning the controller a
locally compatible IP address.
Through a standard Web browser, you can utilize the BIS M-
626’s
HTTP Server
to access an
embedded suite of controller configuration tools, called the “
OnDemand Utilities
.” Among its
features is the
ability to modify and save changes to the controller’s IP address, which is
stored internally on the BIS M-626.
BIS M-626 Industrial Ethernet RFID Controller - Default IP Address:
192.168.253.110
Setting the BIS M-626 IP Address
To set the BIS M-626
’s IP address using the
HTTP Server,
follow the steps below:
1. Open a Web browser on the PC.
2. In the URL address field, enter the BIS M-
626’s IP address (
192.168.253.110 =
factory default
).
3. Press
ENTER
.
The
HTTP Server - Main Page
will be displayed.
HTTP Server
– Main Page
Figure 47 - The HTTP Server - Main Page
The
HTTP Server - Main Page
lists the IP address and network settings currently stored on
the BIS M-626.
Summary of Contents for BIS M-370-000-A02
Page 1: ......
Page 2: ......
Page 3: ......
Page 7: ......
Page 16: ...9 BIS M 371 000 A01 BIS M 372 000 A01 BIS M 373 000 A01 BIS M 370 000 A02 Figure G...
Page 17: ...10...
Page 21: ...BIS M 62_ MANUAL 14 1...
Page 60: ...INSTALLATION 53 2...
Page 77: ...BIS M 62_ MANUAL 70 4...
Page 101: ...BIS M 62_ MANUAL 94 5...
Page 103: ...BIS M 62_ MANUAL 96 6 The HTTP Server Main Page will be displayed...
Page 126: ...DEVICENET INTERFACE 119 8...
Page 185: ...BIS M 62_ MANUAL 178 10...
Page 188: ...RFID OPERATING PRINCIPLES 181 11...