BIS M-62_ MANUAL
136
9
(See the
Green
changes below)
Output Buffer
Input Buffer
Byte #
Value
Byte #
Value
00:
81
Output Buffer Control Byte
(OBCB)
7 6 5 4 3 2 1 0
[1] [0] [0] [0] [0] [0] [0] [1]
00
81
Input Buffer Control Byte
(IBCB)
7 6 5 4 3 2 1 0
[1] [0] [0] [0] [0] [0]
[0]
[1]
01:
00
(Always 0)
01:
00
(Always 0)
02:
0C
(Packet length in bytes)
02:
0E
(Packet length in bytes)
03:
04:
05:
06:
07:
08:
09:
10:
11:
12:
13:
14:
15:
16:
17:
18:
19:
20:
..
30:
00
06
AA
07
00
01
03
E8
00
00
00
00
00
00
00
00
00
00
..
00
(CBx Command word length MSB)
(CBx Command word length LSB)
(CBx Command Type)
(CBx Command Opcode)
(CBx Command, byte not used)
(CBx Command “Node ID”)
(CBx Command Timeout MSB)
(CBx Command Timeout LSB)
(CBx Command Not Used)
(CBx Command Not Used)
(CBx Command Not Used)
(CBx Command Not Used)
03:
04:
05:
06:
07:
08:
09:
10:
11:
12:
13:
14:
15:
16:
17:
18:
19:
20:
..
30:
00
07
FF
FF
00
01
01
01
00
13
22
01
07
00
00
00
00
00
..
00
(CBx Response word length MSB)
(CBx Response word length LSB)
Minimum of 6 words
(CBx Response Type) FF=Error
(CBx Response Opcode) FF=Error
(CBx Response Instance Counter)
(CBx Response “Node ID”)
(CBx Response Timestamp Month)
(CBx Response Timestamp Day)
(CBx Response Timestamp Hour)
(CBx Response Timestamp Minute)
(CBx Response Timestamp Second)
(CBx Response “Data length”)
1 byte (the Error Code)
(CBx Response Data Byte 1)
Error Code 7 = (Tag Not Found)
(CBx Response byte not used)
31:
81
Data Consistency Byte (OBDCB)
31:
81
Data Consistency Byte (IBDCB)
We will assume that the Slave successfully reads the RFID tag.
The Slave writes the response into the Input Buffer, and toggles
Bit 0
of the
IBCB & IBDCB
to indicate that the response is ready.
NOTE
If the master has not acknowledged receiving the previous response, the
processor unit will not be able to place the response in the Input Buffer.
Summary of Contents for BIS M-370-000-A02
Page 1: ......
Page 2: ......
Page 3: ......
Page 7: ......
Page 16: ...9 BIS M 371 000 A01 BIS M 372 000 A01 BIS M 373 000 A01 BIS M 370 000 A02 Figure G...
Page 17: ...10...
Page 21: ...BIS M 62_ MANUAL 14 1...
Page 60: ...INSTALLATION 53 2...
Page 77: ...BIS M 62_ MANUAL 70 4...
Page 101: ...BIS M 62_ MANUAL 94 5...
Page 103: ...BIS M 62_ MANUAL 96 6 The HTTP Server Main Page will be displayed...
Page 126: ...DEVICENET INTERFACE 119 8...
Page 185: ...BIS M 62_ MANUAL 178 10...
Page 188: ...RFID OPERATING PRINCIPLES 181 11...