6.8
Switching Signal Channels, SSC
With the BIP sensor you can program four independent
switching states (Switching Signal Channels, SSCs).
Each switching signal is configured using profile-specific
parameters (see Tab. 6-10). Configuring the switching
channel begins by setting the channel using Index 0x003A.
Index
Parameters
Subindex
Parame-
ters
Data format
Access
Data
0x003A
Teach-In Channel
Setting
0x00
UINT8
R/W
0x01: SSC1
0x02: SSC2
0x03: SSC3
0x04: SSC4
0x003B
Teach-In Status
0x00
UINT8
R
0x003C
Set Point value
(SSC1)
0x01
Setpoint1
INT16
R/W
–32000…+32000
0x02
Setpoint2
INT16
R/W
–32000…+32000
0x003D
Switching Signal
configuration SSC1
0x01
logic
UINT8
R/W
0x00 : normal mode
0x01: inverted mode
0x02
mode
UINT8
R/W
0x01: Single point
0x02: Window mode
0x03 Two Point mode
0x03
hysteresis
INT16
R/W
50…16900 μm
0x003E
Set Point value
(SSC2)
0x01
Setpoint1
INT16
R/W
–32000…+32000
0x02
Setpoint2
INT16
R/W
–32000…+32000
0x003F
Switching Signal
configuration SSC2
0x01
logic
UINT8
R/W
0x00 : normal mode
0x01: inverted mode
0x02
mode
UINT8
R/W
0x01: Single point
0x02: Window mode
0x03 Two Point mode
0x03
hysteresis
INT16
R/W
50…16900 μm
0x4000
Set Point value
(SSC3)
0x01
Setpoint1
INT16
R/W
–32000…+32000
0x02
Setpoint2
INT16
R/W
–32000…+32000
0x4001
Switching Signal
configuration SSC3
0x01
logic
UINT8
R/W
0x00 : normal mode
0x01: inverted mode
0x02
mode
UINT8
R/W
0x01: Single point
0x02: Window mode
0x03 Two Point mode
0x03
hysteresis
INT16
R/W
50…16900 μm
0x4002
Set Point value
(SSC4)
0x01
Setpoint1
INT16
R/W
–32000…+32000
0x02
Setpoint2
INT16
R/W
–32000…+32000
0x4003
Switching Signal
configuration SSC4
0x01
logic
UINT8
R/W
0x00 : normal mode
0x01: inverted mode
0x02
mode
UINT8
R/W
0x01: Single point
0x02: Window mode
0x03 Two Point mode
0x03
hysteresis
INT16
R/W
50…16900 μm
Tab. 6-10: Profile-specific parameters
6
IO-Link interface (continued)
Based on the Smart Sensor profile the Parameter
Switching Signal configuration can be used to set the
behavior of the switching points:
– Single-point mode, (Fig. 6-2): Value: 1
– Two-point mode, (Fig. 6-3): Value: 3
– Windowed mode, (Fig. 6-4): Value: 2
Switching signals can only be taught as long as
the position value is valid.
www.balluff.com
17
english
BIP LD2-T017-01-EP _ _ / EP _ _ -S4
Inductive Positioning System
Summary of Contents for BIP LD2-T017-01-EP-S4 Series
Page 2: ...www balluff com...
Page 3: ...BIP LD2 T017 01 EP_ _ BIP LD2 T017 01 EP_ _ S4 Betriebsanleitung deutsch...
Page 4: ...www balluff com...
Page 32: ......
Page 33: ...BIP LD2 T017 01 EP_ _ BIP LD2 T017 01 EP_ _ S4 User s Guide english...
Page 34: ...www balluff com...
Page 62: ......
Page 63: ...BIP LD2 T017 01 EP_ _ BIP LD2 T017 01 EP_ _ S4 Notice d utilisation fran ais...
Page 64: ...www balluff com...
Page 92: ......
Page 93: ...BIP LD2 T017 01 EP_ _ BIP LD2 T017 01 EP_ _ S4 Manuale d uso italiano...
Page 94: ...www balluff com...
Page 122: ......
Page 123: ...BIP LD2 T017 01 EP_ _ BIP LD2 T017 01 EP_ _ S4 Manual de instrucciones espa ol...
Page 124: ...www balluff com...
Page 152: ......
Page 153: ...BIP LD2 T017 01 EP_ _ BIP LD2 T017 01 EP_ _ S4...