61
Qhyst
Compensation for the serving cell in the reselection
evaluation. See parameter Q
hyst
in 3GPP 36.304.
Range: 0-6, 8,10,12,14,16,18,20,22,24 dB
Default: 3 dB
Allowed Meas BW
Measurement bandwidth allowed.
Options: Null, 1.4 MHz, 3 MHz, 5 MHz, 10 MHz, 15 MHz, or 20
MHz
Default: 20 MHz
Additional Measurement Parameter (Figure 5-39):
mobilityType
Designated mobility type of the UE’s consequent action after
the measurement event reporting.
Options:
Blind_redirect
Irat_data
Irat_voice
measEvent
Defines the event type of measurement report.
Options:
EVENT_A2
EVENT_B2 - only mapping to Irat_voice
eutranThresholdRsrp
RSRP threshold to be used in EUTRA measurement report
triggering condition for events A2 and A5.
Range: 0 to 97
eutranThresholdRsrq
RSRQ threshold to be used in EUTRA measurement report
triggering condition for events A2 and A5.
Range: 0 to 34
Hysteresis
Hysteresis value applied to entry and leave condition of a
report triggering event. The actual value will be the configured
value x 0.5. Refer to 3GPP 36.331 6.3.5.
Range: 0 to 30
Time To Trigger
Concerns the time during which specific criteria for the event
need to be met in order to trigger a measurement report.
Refer to 3GPP 36.331 6.3.5.
Options: 0, 40, 64, 80, 100, 128, 160, 256, 320, 480, 512, 640,
1024, 1280, 2560, 5120 ms
Default: 0 ms
eutranTriggerQuantity The quantities used to evaluate the triggering condition for
the event for the .Reference Signal Received Power (RSRP) and
Reference Signal Received Quality (RSRQ) value, as specified in
3GPP 36.331 6.3.5.
Options:
RSRP
RSRQ
A2reportQuantity
Measurement quantities to be included in the A2
measurement report.
Summary of Contents for Neutrino-224
Page 1: ...Neutrino 224 Indoor 2x125mW FDD TDD eNodeB Installation Guide December 2018 Version 1 7...
Page 20: ...20 Figure 4 7 FDD eNB GUI Home Page Figure 4 8 TDD eNB GUI Home Page...
Page 47: ...47 Figure 5 24 LTE Neigh Freq Settings 1 of 2 Figure 5 25 LTE Neigh Freq Settings 2 of 2...
Page 64: ...64 Figure 5 38 Cell ReSelection Parameter Figure 5 39 Additional Measurement Parameter...