55
5.5.1.5.1
Neigh Freq List
1.
In the eNB GUI go to LTE Setting > GSM Freq/Cell (Figure 5-29).
Figure 5-29: GSM Freq/Cell
2.
Under
Neigh Freq List
, click on the
Add
icon
to add the neighboring GSM eNBs’
frequencies (up to 12). Each field is described in Table 5-17. Click on
Save
after setting
the values.
Table 5-17: Neigh Freq List
Parameter Name
Description
qRxLevMin
Minimum access level. Only when the received signal power
measured by the UE is higher than this threshold will the UE be
allowed to connect to this cell.
Reselection Priority
Priority of the reselection to cells at this frequency
threshXHigh
Reselection threshold for higher priority inter-band frequency.
This parameter represents the access threshold level at which
the UE will leave the serving cell and reselect another cell at
the target frequency, given that the target frequency cell has a
cell reselection priority higher than the serving one
threshXLow
Reselection threshold for lower priority inter-band frequency.
This parameter represents the access threshold level at which
the UE will leave the serving cell and reselect another cell at
the target frequency, given that the target frequency cell has
an absolute priority lower than the serving one.
bandIndicator
DCS1800/PSC1900 frequency band indicator
bcchArfcn
ARFCN for GSM neighbor frequency
nccPermitted
Permitted NCC of the neighbor cell
pMaxGeran
The allowed max upload transmitted power
arfcnSpacing
ARFCN interval of frequency point list.
numOfFollowingArfcns ARFCN number of frequency point list
Summary of Contents for Neutrino-224
Page 1: ...Neutrino 224 Indoor 2x125mW FDD TDD eNodeB Installation Guide December 2018 Version 1 7...
Page 20: ...20 Figure 4 7 FDD eNB GUI Home Page Figure 4 8 TDD eNB GUI Home Page...
Page 47: ...47 Figure 5 24 LTE Neigh Freq Settings 1 of 2 Figure 5 25 LTE Neigh Freq Settings 2 of 2...
Page 64: ...64 Figure 5 38 Cell ReSelection Parameter Figure 5 39 Additional Measurement Parameter...