Preliminary User Manual UMAX023241 - Version: 1.1 52-63
1.4.26.
2452h PID Derivative Gain
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
2452
0
INT16
RW
No
0-100
10
Additional PID controller derivative gain
1.4.27.
2453h PID Target Source
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
2453 0
UINT8 RW
No
0-10 0
By default disabled, see
Table 6
1.4.28.
2454h PID Target Number
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
4254 0
UINT8 RW
No
0-16 1
By default disabled, see
Table 7
1.4.29.
2455h PID Feedback Source
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
2455 0
UINT8 RW
No
0-10 0
By default disabled, see
Table 6
1.4.30.
2456h PID Feedback Number
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
4256 0
UINT8 RW
No
0-16 1
By default disabled, see
Table 7
1.4.31.
2457h PID Control Response
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
4257
0 UINT8
RW
No
0-3
0 Additional
PID controller response selection
1.4.32.
2460h PID Output FV
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
4260
0
INT16
RO
Yes
0-1000
0
Additional PID controller output FV
1.4.33.
2500h EC Extra Received PV
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
2500
0
UINT8
RO
Yes
6
6
Number of subindexes
1
INT16
RW
INT16
0
Extra received PV 1
2
Extra received PV 2
3
Extra received PV 3
4
Extra received PV 4
5
Extra received PV 5
6
Extra received PV 6