Preliminary User Manual UMAX023241 - Version: 1.1 36-63
1.2.16.
1600h RPDO 1 Mapping Parameters
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
1600
0
UINT8
RW
No
0-4
2
Number of subindexes
1
UINT32
UINT32 0x73000110
Output #1 FV
2
0x73000210
Output #2 FV
3
0
Not used by default
4
0
Not used by default
1.2.17.
1601h RPDO 2 Mapping Parameters
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
1601
0
UINT8
RW
No
0-4
4
Number of subindexes
1
UINT32
UINT32 0x25000110
EC Extra Received PV Value 1
2
0x25000210
EC Extra Received PV Value 2
3
0x25000310
EC Extra Received PV Value 3
4
0x25000410
EC Extra Received PV Value 4
1.2.18.
1602h RPDO 3 Mapping Parameters
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
1602
0
UINT8
RW
No
0-4
0
Number of subindexes
1
UINT32
UINT32 0x25000510
EC Extra Received PV Value 5
2
0x25000610
EC Extra Received PV Value 6
3
0
Not used by default
4
0
Not used by default
1.2.19.
1603h RPDO 4 Mapping Parameters
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
1603
0
UINT8
RW
No
0-4
0
Number of subindexes
1
UINT32
UINT32 0
Not used by default
2
0
Not used by default
3
0
Not used by default
4
0
Not used by default
1.2.20.
1800h TPDO 1 Communication Parameters
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
1800
0
UINT8
RO
No
5
5
Number of subindexes
1 UINT32
RW
UINT32
0x400001FF
COB-ID
2 UINT8
UINT8
0xFE
Transmission
type
3 UINT16
UINT16
0
Inhibit
time
4 UINT8
UINT8
0
Compatibility
entry
5 UINT16
UINT16
0x64 Event
timer