Preliminary User Manual UMAX023241 - Version: 1.1 29-63
The module will send the following response (any other response is a failure).
Item Value
COB-ID 0x7E4
Length 3
Data 0
0x11
(cs=17 for configure node-id)
Data 1
0x00
Data 2
0x00
Save the configuration by
sending
the following message:
Item Value
COB-ID 0x7E5
Length 1
Data 0
0x17
(cs=23 for store configuration)
The module will send the following response (any other response is a failure)
Item Value
COB-ID 0x7E4
Length 3
Data 0
0x17
(cs=23 for store configuration)
Data 1
0x00
Data 2
0x00
Set the module state to LSS-operation by
sending
the following message: (Note, the
module will reset itself back to the pre-operational state)
Item Value
COB-ID 0x7E5
Length 2
Data 0
0x04
(cs=4 for switch state global)
Data 1
0x00
(switches to waiting state)
1.1.1.2. Setting Baud rate
Set the module state to LSS-configuration by sending the following message:
Item Value
COB-ID 0x7E5
Length 2
Data 0
0x04
(cs=4 for switch state global)
Data 1
0x01