Preliminary User Manual UMAX023241 - Version: 1.1 62-63
Electrical Connections
12 pin Deutsch IPD connector P/N: DTM13-12PA-R008
20 AWG wire is recommended for use with contacts 0462-201-20141.
CAN and I/O Connector
Pin #
Description (Notes)
1 BATT
-
2 CAN_L
3 CAN_H
4
P_GND (Out 1 and Out 2)
5
Analog _GND (Input 1 and Input 2)
6 Input
1+
7 Input
2+
8 +5V
Ref
9
Output 2+ (Default: Not Used)
10 Output
1+
11 CAN_Shield
12 BATT
+
Mating Plug Kit
Axiomatic P/N:
PL-DTM06-12SA
. It is comprised of the following Deutsch IPD
parts: plug (DTM06-12SA); wedgelock (WM12S); and 12 contacts (0462-201-
20141) as well as 6 sealing plugs (0413-204-2005).
Installation
Mounting holes sized for ¼ inch or M6 bolts. The bolt length will be determined by
the end-user’s mounting plate thickness. The mounting flange of the controller is
0.63 inches (16 mm) thick. All field wiring should be suitable for the operating
temperature range, rated voltage and current. Wiring to the product must be in
accordance with all applicable local codes. Install the unit with appropriate space
available for servicing and for adequate wire harness access (6 inches or 15 cm)
and strain relief (12 inches or 30 cm).
Network Termination
It is necessary to terminate the network with external termination resistors. The
resistors are 120 Ohm, 0.25W minimum, metal film or similar type. They should be
placed between CAN_H and CAN_L terminals at both ends of the network.