Preliminary User Manual UMAX023241 - Version: 1.1 34-63
1.2.6. 1011h Restore Parameters
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
1011
0 UINT8
RO
No
4
4 Number
of
subindexes
1 UINT32
RW
load
1 Write
0x4616F6C
(‘d’, ‘a’, ‘o’, ‘l’) for restoring ALL
parameters
2
Write 0x4616F6C (‘d’, ‘a’, ‘o’, ‘l’) for restoring
Communication parameters
3
Write 0x4616F6C (‘d’, ‘a’, ‘o’, ‘l’) for restoring
Application parameters
4
Write 0x4616F6C (‘d’, ‘a’, ‘o’, ‘l’) for restoring
Manufacturer parameters
1.2.7. 1016h Consumer Heartbeat Time
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
1016
0 UINT8
RO
No
4
4 Number
of
subindexes
1 UINT32
RW
UINT32
0 Consumer
heartbeat
time
bits 31-24: reserved
bits 23-16: Node ID
bits 15-0: heartbeat time in milliseconds
2
3
4
1.2.8. 1017h Producer Heartbeat Time
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
1017 0
UINT16 RW
No
10-
65000
0
Producer heartbeat time in milliseconds
1.2.9. 1018h Identity Object
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
1018
0
UINT8
RO
No
4
4
Number of subindexes
1 UINT32
UINT32
0x55
Vendor
ID (Axiomatic Technologies)
2 0xAA023241
Product
Code
3
Revision
Number
4 Serial
Number
1.2.10.
1020h Verify Configuration
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
1020
0
UINT8
RO
No
4
4
Number of subindexes
1 UINT32
UINT32
Configuration date: DD-MM-YYYY
2
Configuration time: HH-MM