18
2 Hardware Installation
3.
Remove the back covers of the inserts.
4.
Screw the cable onto connector strip X2 on the
terminal board.
See Table 1 in Appendix C, Tables, for the pin
assignments to connect the AVM ISDN-Control-
ler T1/T1-B’s cable to the terminal strip.
5.
Connect the cable leads to the correct terminals
on the terminal strip.
6.
Replace the cover over the terminals and lock it.
2.3.2 Connection to the NTPMKU or NTPMGF
(NTs with T-shaped Mounting Element)
1.
Connect the 9-pin sub-D connector of the cable to
the 9-pin socket of the AVM ISDN-Controller
T1/T1-B (see Fig. 3 in Appendix B, Illustrations).
Secure the connection by tightening the finger
screws. Route the 6 meter cable as directly as
possible to the NT.
2.
Unlock and remove the cover of the NTPMKU or
NTPMGF connection terminals.
3.
In the NT there is a T-shaped mounting element for
the connecting cable (see Fig. 4 in Appendix B,
Illustrations). Open it to affix the cable by undoing
the screws.
See Table 2 or Table 3, depending on your NT
type, in Appendix C, Tables, for the pin assign-
ments to connect the AVM ISDN-Controller T1/
T1-B’s cable leads to the NTPMKU or NTPMGF
terminals.