Installing and wiring telephones and trunks
Installing the Avaya S8700 Media Server with an Avaya G650 Media Gateway
213
December 2003
Installing off-premises station wiring
The local telephone company provides cabling outside the building for off-premises stations. The off-
premises stations can appear on any of the RJ21X network interfaces provided for the central office (CO)
trunks.
CAUTION:
Only an FCC-approved (or equivalent) analog type telephone (such as a 2500-type), can
be used as an off-premises station. The TN746B and TN2183 Analog Line circuit packs
can be connected to off-premises stations.
1
Install an A25D (male to male) cable between the RJ21X network interface and a sneak fuse
panel.
2
At the main distribution frame (MDF), connect jumper wires between one row/connecting block
in the green field and up to three rows/connecting blocks in the purple field to concentrate the
analog line pairs.
3
Connect an A25D cable between the sneak fuse panel and the terminal block connector associated
with the green row in the previous step.
4
Install a green label on the terminal block to identify the remote location.
5
Administer per the Administrator’s Guide for Avaya Communication Manager.
Table 25: Port circuit pack and telephone pin designations
Pin on
modular
plug
4-wire: 8400-
series,
606A1
2-wire: 302D,
8400-series,
603E
8510T BRI
(with
adjunct
speaker
phone)
Analog
station,
modem
NT1
1
TXT
2
TXR
T
3
PXT
TXT
R
4
T
PXR
T
5
R
PXT
No Connection
4-pin modular
jack
R
6
PXR
TXR
7
-48VDC
(-48VDC)
(-48VDC)
-48VDC
8
GRD
GRD
GRD
GRD
Circuit Pack
TN754 4-wire
digital (8 port)
TN2181 2-wire
digital (16 port)
TN2224 2-wire
digital (24 port)
TN556 ISDN-
BRI Line
TN2183
Analog line (16
port)
TN2198 2-wire
BRI line
PX
PBX transmitT
Tip (A)
TX
Terminal transmitRRing(B)