![Avaya G650 Installation Instructions Manual Download Page 171](http://html1.mh-extra.com/html/avaya/g650/g650_installation-instructions-manual_3027012171.webp)
Installing the Avaya S8700 Media Server with an Avaya G650 Media Gateway
171
December 2003
Installing sneak fuse panels
For general information, see
Installing sneak current and off premise protection
on page 168.
Figure 66, Model 507B sneak fuse panel,
on page 169, or equivalent, is recommended for sneak current
protection. The panel contains two 25-pair connectors, fuse removal tool, and fifty 220029 sneak fuses
(and two spares). See
Table 13, Sneak fuse connector pinout,
on page 170 for pinout data.
1
Locate the 507B near the network interface or the main distribution frame (MDF).
2
Hold the panel against the mounting surface and mark the mounting screw locations. Drill pilot
holes at the marked locations and partially install a locally obtained #12 x 3/4-inch screw into the
two bottom mounting slots.
3
Slide the sneak fuse panel onto the mounting screws and tighten the screws securely.
4
Install a locally obtained #12 x 3/4-inch screw into the top two mounting slots and tighten
securely.
5
Repeat the procedure for each sneak fuse panel.
6
Secure the B25A cable to the panel with the captive screw on the connector and a supplied cable
tie.