1 Overview
© Copyright Reserved Autonics Co., Ltd.
25
1.7.3
Ethernet Interface
Downloading the drawing data of atDesigner by connecting with PC.
Also possible to communicate with some PLC that can be connected by Ethernet communication.
In case of connecting with LAN cable and Hub, use direct cable and in case of connecting to
computer directly, use cross cable.
(1)
Direct cable
PC1
Cable color
PC2
Signal Pin no.
Pin no. Signal
Tx+
1
White
Orange
1
Rx+
Tx-
2
Orange
2
Rx-
Rx+
3
White
Green
3
Tx+
4
Blue
4
5
White
Blue
5
Rx-
6
Green
6
Tx-
7
White
Brown
7
8
Brown
8
Tx: Transmit Data
Rx: Receive Data
(2)
Cross cable
PC1
Cable color
PC2
Signal Pin no.
Pin no. Signal
Tx+
1
White
Orange 1
Rx+
Tx-
2
Orange
Rx-
Rx+
3
White
Green
3
Tx+
4
Blue
5
White
Blue
5
Rx-
6
Green
Tx-
7
White
Brown
7
8
Brown
Tx: Transmit Data
Rx: Receive Data
Summary of Contents for LP-A Series
Page 2: ...ii Copyright Reserved Autonics Co Ltd ...
Page 27: ...1 Overview Copyright Reserved Autonics Co Ltd 27 1 8 Dimension 1 8 1 LP A070 unit mm ...
Page 28: ...1 Overview 28 Copyright Reserved Autonics Co Ltd 1 8 2 LP A104 unit mm ...
Page 29: ...1 Overview Copyright Reserved Autonics Co Ltd 29 1 8 3 Common ...
Page 30: ...1 Overview 30 Copyright Reserved Autonics Co Ltd ...
Page 38: ...2 Installation 38 Copyright Reserved Autonics Co Ltd ...
Page 46: ...3 System Organization 46 Copyright Reserved Autonics Co Ltd ...
Page 66: ...6 Troubleshooting 66 Copyright Reserved Autonics Co Ltd ...
Page 70: ...7 Repair Maintenance Inspection 70 Copyright Reserved Autonics Co Ltd ...
Page 105: ...9 Appendix Copyright Reserved Autonics Co Ltd 105 ...