16
CONTROL BOARD ADJUSTMENTS (cont)
MENU 7 OPERATING MODES (cont)
VACATION MODE
Vacation mode can be turned on or off using this parameter.
BATTERY / SOLAR MODE
The controller can be instructed to turn off the battery backup
facilities so that the control board can be shut down without hav-
ing to disconnect the battery backup system.
PASSWORD PROTECTION
The password feature enables all parameters and configuration
settings to be protected unless a password is entered. When this
feature is turned on the user is requested to enter the desired pass-
word to be used. The password protection feature has a timeout
that expires after 60 seconds of inactivity. Alternately the user
may log out manually by pressing exit when the main screen is
displayed.
TRANSMITTER # GROUPING
The transmitter store number display format can be changed to
show a grouped format. When grouping is selected, instead of dis-
playing the store location as a number between 1 and 511, it is dis-
played as ##$ where ## is the group number and $ is a character
a,b,c,d,e,f,g or h which indicates the group member.
OPEN AND STOP INPUT POLARITY
The OPN and STP inputs are normally configured for N/O oper-
ation. These parameters allows the input’s operation to be
changed to N/C.
OUTPUT 1 & 2 FUNCTION
This parameter selects functions assigned to OUTPUTS 1 & 2.
EZYPLOT MOTOR
This parameter selects which motor is used for Ezyplot reporting.
OPEN INPUT = 2ND P.E INPUT
The OPN input can be configured to operate as a 2nd P.E input
with the same P.E input response mode as that selected for the
standard P.E input. The 2nd P.E input is used to alter the P.E trig-
gered auto-close feature so that P.E triggered auto-close is only
initiated when the gateway is exited. The direction of travel is
determined by the sequence in which the two P.E inputs are trig-
gered. The OPN input’s P.E beam is mounted on the inside of the
gateway while the P.E input’s P.E beam is loacted at or outside the
gateway. For an exit to be detected the inputs must be activated in
the following sequence: OPN input activated, P.E input activated
, OPN input deactivated, P.E input deactivated.
PARAMETER
MIN
MAX
DEFAULT STEP UNITS
MENU #
P.E INPUT RESPONSE MODE
Sets the P.E
response mode. Options are OPEN and CLOSE
cycles stop, Close cycles stop or Close cycle
reverse
OPN&CLS stop
CLS to stop
CLS to Reverse
CLS to
Reverse
7
PED INPUT = SWIPE MODE
Selects the PED input
functions as pedestrian access swipe input.
OFF
ON
OFF
7
REMOTE CODE ENABLED
Selects remote transmitter coding function
OFF
ON
ON
7
ACTIVITY REPORTS
Select report to be output
OFF
255
OFF
1
7
ACTIVITY REPORT ID
Selects ID for controller, sent with activity report
0
65535
0
1
7
VACATION MODE
Selects vacation mode - disables remote control.
OFF
ON
OFF
7
BATTERY / SOLAR MODE
Selects Battery Backup / Solar operation
OFF
ON
ON
7
PASSWORD
Selects password protection for all changes.
OFF
ON
OFF
7
TX # GROUPING
Selects tx’er number group display format.
OFF
ON
OFF
7
OPN INPUT N/C OPERATION
Selects operating polarity of OPN input
OFF
ON
OFF
7
STP INPUT N/C OPERATION
Selects operating polarity of OPN input
OFF
ON
OFF
7
OUTPUTS 1&2
Selects function of OUTPUT1 and OUTPUT2
OUT1 = LOCK
OUT2 = LIGHT
OUT1 = LIGHT
OUT2 = LOCK
OUT1 = LOCK
OUT2 = LIGHT
7
EZYPLOT USES MOTOR
Selects motor for Ezyplot reporting
1
2
1
1
7
OPN INPUT = 2ND P.E
Open input acts as 2nd P.E input
OFF
ON
OFF
7