TRANSMITTER EDIT PROCEDURE

19

STEP 1. DISPLAY TRANSMITTER RECORD

Using one of the methods below, display the required transmitters
details.

1.  

Follow the BASIC CODE TRANSMITTER

PROCEDURE to STEP 3 for a new or existing  transmitter.

2.  

Select EDIT when LISTING TRANSMITTERS

STEP 2. SELECTING THE FIELD TO EDIT

Select the desired field by using NEXT or PREV to move the
cursor to the left or right and between the top and bottom lines.

STEP 3. EDITING THE BUTTON FUNCTION FIELDS

Preform this step if one of the button function fields is selected.
Use UP and DOWN to change the displayed value. The available
functions are shown below. Selecting OFF will prevent the 
controller responding to the button at all. When the correct setting
has been made repeat STEP 2 to select the next field to edit or
continue with STEP 7. The example below shows editing the
function assigned to the transmitter button 2. The transmitter in
the example is transmitter number 123 which has a label of AB
Smith.

AVAILABLE FUNCTIONS

VAC

(Vacation Mode)

LGT

(Courtesy Light)

STP

(Stop)

OPN

(Open)

CLS

(Close)

SWP

(Swipe)

PED

(Pedestrian access)

OSC

(Open/Stop/Close)

OFF

(No action)

STEP 4. EDITING THE STORE LOCATION

This feature is only available when editing is initiated by coding
the first button of a new transmitter. When the cursor is moved to
the store number field, the UP and DOWN buttons step through
the available store locations. This is useful when managing 
transmitters using a scheme which ties the store location to the
transmitter’s owner.

STEP 5. SELECTION OF ID OR SN DISPLAY

When the cursor is moved to the ID/SN indicator, the UP and
DOWN buttons toggle between displaying the ID label and the
transmitters serial number The serial number display is provided
for an additional means of transmitter management. The
transmitter in the example has a serial number of 123456789. 

STEP5. EDITING A CHARACTER FIELD

Preform this step if one of the character fields of the transmitter
name is selected.  Press UP or DOWN to change the selected

character. When a change is made the bottom line of the display
will show a list of available characters to choose from with the
current value indicated at the cursor position. When the correct
character has been selected repeat STEP 2 to select the next field
to edit or continue with STEP 7.

STEP 7. SAVING THE CHANGES 

Press SET to save the settings or EXIT to abort without saving.

NOTE

If all button functions are set to OFF then when SET is

pressed, the controller will prompt to confirm the transmitter.is to
be deleted. Press SET to delete or EXIT to continue editing.

 

 

PRESS 

THE PROCEDURE BELOW IS USED TO EDIT THE DISPLAYED TRANSMITTER’S SETTINGS.

 

123 

 

I

ID

 

 B 

 SMITH

OSC 

 PED 

 LGT 

 VAC

 

PRESS 

Selecting Button Function

D

 

PRESS 

 

124 

 

I

ID

 

 B 

 SMITH

OSC 

 PED 

 LGT 

 VAC

Character For Name Selected

A

 

124 

 

I

ID

 

 B 

 SMITH

56789 

 AB 

 CDEFGHIJ

 

PRESS 

Character For Name Edited

B

 

124 

 

I

ID

 

 B 

 SMITH

OSC 

 PED 

 LGT 

 VAC

Saving Changes

 

PRESS 

124 

 

I

ID

 

123456789

OSC 

 PED 

 LGT 

 VAC

Displaying Serial Number

S

SN

N

B

 

 

PRESS 

123 

 

I

ID

 

 B 

 SMITH

OSC 

 PED 

 LGT 

 VAC

4

 

PRESS 

Selecting a Shore Location Number

Summary of Contents for CB-19

Page 1: ...COPY Warning Failure to comply with the installation instructions and the safety warnings may result in serious personal injury and or property opener or controller damage Installation Instructions C...

Page 2: ...GARAGE DOOR OPENERS GATE OPENERS REMOTE CONTROL ACCESS SOLUTIONS...

Page 3: ...ING UP THE CONTROLLER 7 SETUP TRAVEL 7 LIMIT SWITCH AMP TRAVEL SETUP 9 RE PROFILING TRAVEL 10 SETTING TIMED TRAVEL 11 SETTING PEDESTRIAN POSITION 12 DESCRIPTION OF STANDARD OPERATION 13 CONTROL BOARD...

Page 4: ...d for the installer to touch any console buttons during the coding process When all transmitters are coded a trans mitter storage report can be generated which can be easily transferred to a P C for r...

Page 5: ...al 2 16 MOTOR 2 close limit switch input terminal 17 MOTOR 2 open limit switch input terminal 18 COM terminal for Terminals 16 17 19 20 19 MOTOR 1 close limit switch input terminal 20 MOTOR 1 open lim...

Page 6: ...ansmitter Testing See Page 23 Event History Display See Page 23 Memory Usage See Page 23 Periodic Service Cycle Counter See Page 24 Parameter List 1 Open Lock Time 2 Close Lock Time 3 Pre Opn Lock Tim...

Page 7: ...NG CONTROL SWITCH INPUTS When remote control operation is only required the CB 19 s con trol switch inputs are not utilised It is however strongly advised that a Photo electric Safety Beam be used to...

Page 8: ...borted at anytime by pressing EXIT STEP 1 NAVIGATING TO LIMIT AMP TRAVEL MENU To navigate to the Menu 10 1 from the MAIN SCREEN simply press PREVto display MENU 10 followed by SET to display MENU 10 1...

Page 9: ...console keypad or Button 1 and 4 of a transmitter After making adjustments to the limit switch positions always re approach the limit at full speed by driving the motor close a short distance and then...

Page 10: ...lly close and open gate several times and learn the gates load and travel characteristics When the setup is complete the MAIN SCREEN will be displayed with the gate shown to be OPEN The Gate can now b...

Page 11: ...g up the travel times The first allows the installer to drive the motor s so that the actual travel time can be recorded The second allows exact times to be entered Note The limit setting procedure ca...

Page 12: ...me Save Settings PRESS Confirming Settings SETTING TIMED TRAVEL ENTER TIMES STEP 5A ENTERING TIMED TRAVEL PARAMETERS When the ENTER TIMES method is selected a list of parameters is provided to configu...

Page 13: ...Activated by PED terminal with N O switch or by transmitter button with PED Function assigned The pedestrian access operation partly opens the gate to allow pedestrian access but prevent vehicle acce...

Page 14: ...pplies 0 1 25 5 1 0 0 1 SEC 2 AMP TRIP LIMIT Motor drive electronics current limit 0 13 13 1 AMPS 2 PARAMETER AMP LIMITS MIN MAX DEFAULT STEP UNITS MENU MOTOR 1 OPEN LIMIT AMPS Sets Motor 1 open limit...

Page 15: ...tions for safety reasons A P E beam must be used for these features to be activated AUTO CLOSE AFTER POWER UP Auto close after power up is normally not enabled for safety rea sons but can be enabled i...

Page 16: ...configured to a SWIPE type input for pedestrian access This provides full functionality with the P E Triggered Pedestrian auto close function REMOTE CODE The controller supports the Remote Code Set fe...

Page 17: ...input is used to alter the P E trig gered auto close feature so that P E triggered auto close is only initiated when the gateway is exited The direction of travel is determined by the sequence in whi...

Page 18: ...yed Using the NEXT PREV buttons step through the list of parameters until the required parameter is displayed If the parameter s value is not to be changed then skip to step 7 when finished viewing th...

Page 19: ...ode Transmitter menu will now be shown Press EXIT to return to the MAIN SCREEN and test the transmitter MENU 1 Code Transmitter PRESS Starting Code Transmitter Procedure Press Tx er Button LIST Press...

Page 20: ...cheme which ties the store location to the transmitter s owner STEP 5 SELECTION OF ID OR SN DISPLAY When the cursor is moved to the ID SN indicator the UP and DOWN buttons toggle between displaying th...

Page 21: ...tter s location within the list NOTE VIEW will not be shown if the transmitter is not stored 20 THE CONTROLLER PROVIDES A TRANSMITTER LISTING FACILITY WHICH ENABLES THE USER TO FIND A TRANSMITTER LOCA...

Page 22: ...code operation is selected for a location that already contains a transmitter then the BASIC CODE TRANSMITTER PROCEDURE will be initiated and the new transmitter will replace the existing one Note tha...

Page 23: ...for 2 seconds The example shows Button 1 being used but it could be any button It can even be an unused button on the existing transmitter STEP 5 CONFIRM TRANSMITTER BUTTON TO BE CODED Within 10 seco...

Page 24: ...be displayed that shows the transmitter details along with the button pressed The example below shows the case when transmitter number 124 is activated by button 4 Note ID is selected for display MENU...

Page 25: ...1234 When finished viewing simply press EXIT 24 Viewing Service Counter Service Counter CYCLES 60000 Viewing Counters 1 Open Cycles 1234 1 Open Cycles 2 Close Cycles 3 Ped Cycles 4 Warranty Cycles 5...

Page 26: ...VAC 24VAC 30VDC 5AMPS RECEIVER TYPE UHF 433 92 MHz AM Receiver RECEIVER CODE STORAGE CAPACITY 30 x 4 Button Transmitter Codes TRANSMITTER FREQUENCY 433 92 MHz CODING TYPE Hopping Code No of CODE COMBI...

Page 27: ...aims any liability of whatsoever nature in respect of any claim or demand loss or damage which arise out of a accidental damage to or normal wear and tear to the Product or to the Product s components...

Page 28: ...GARAGE DOOR OPENERS GATE OPENERS REMOTE CONTROL ACCESS SOLUTIONS...

Reviews: