7-15
CONNECTION OF SERVICES
2.2
Activating the System
The EC700 system has a shutdown feature
that can be used when the vehicle is in
storage. This allows the leisure electronics to
be turned off when not required to save
battery power. When in the off state the alarm
and tracking system supplies are still active,
most other supplies are turned off.
Before using the system please ensure the
system shutdown switch is in the on position
(button in) the system is now active.
2.3
Connecting to the Mains 230V
supply and Safety checks
For your safety it is IMPORTANT that you
follow these connections instructions each
time your motorhome is connected to a
mains supply. This section assumes that the
system is complete and that a Leisure battery
has been installed (see 3.4).
A)
Ensure suitability of the Mains Supply.
Your motorhome should only be
connected to an approved supply that
meets the requirements of BS7671 or
relevant harmonised standards. In most
cases the site warden will hold
information regarding suitability of supply.
If using a generator you also need to
comply with the requirements /
instructions supplied with the generator.
Please note that some electronic
generators may not be compatible with
your leisure system. Further generator
operational information is contained
elsewhere in this manual.
B)
Switch the PSU internal Power
Converter OFF
. Locate the green
‘Charger’ power switch on the PSU and
ensure the switch is in the off position
(button out) before connection to the
mains supply.
C)
Connect the Hook-up Lead
. Firstly,
connect the supplied hook-up lead
(orange cable with blue connectors) to
the Leisure Vehicle and then connect to
the mains supply.
D)
Check Residual Current Device
Operation
. Locate the RCD within the
PSU and ensure the RCD is switched on
(lever in up position). Press the ‘Test’
button and confirm that the RCD turns off
(lever in down position). Switch the RCD
back to the on position (lever in up
position). If the test button failed to
operate the RCD see section 3.18.
E)
Check Miniature Circuit Breakers
.
Locate the MCB’s within the PSU
(adjacent to the RCD) and ensure they
are all in the on (up) position. If any
MCB’s fail to ‘latch’ in the on position see
section 3.18.
F)
Turn the PSU ON
. Locate the black
‘Shutdown’ button and ensure it is in the
on position (press button in). Locate the
green ‘Charger’ switch on the PSU and
turn to the on position (press button in).
The charger switch will illuminate when
turned on.
G)
Check correct Polarity
. Locate the
‘Reverse polarity’ indicator on the PSU
and ensure that the indicator is NOT
illuminated. If the indicator is illuminated
see section 3.18.
H)
Check operation of equipment
. It is
now safe to operate the 12v and 230v
equipment.
Summary of Contents for Symbol Plus 2018
Page 6: ...1 4 ...
Page 10: ...2 4 MOTORHOME CODE ...
Page 16: ...5 2 ARRIVAL AT SITE ...
Page 58: ...7 34 CONNECTION OF SERVICES 12V WIRING DIAGRAM ...
Page 59: ...7 35 CONNECTION OF SERVICES 230V WIRING DIAGRAM ...
Page 60: ...7 36 CONNECTION OF SERVICES ...
Page 93: ...9 29 FITTED EQUIPMENT CONNECTION OF TV SATELLITE SYSTEM STANDARD ...
Page 94: ...9 30 FITTED EQUIPMENT CONNECTION OF TV SATELLITE SYSTEM WITH OPTIONAL MEDIA PACK ...
Page 104: ...9 40 FITTED EQUIPMENT ...
Page 124: ...12 10 SERVICE DETAILS ...
Page 126: ...13 2 NOTES Designed and Printed by Preset Graphics Tel 01332 549278 HB1131 MY 2018 Ref 21627 ...