5.3.1.3. Motor connection compartment: close
Figure 27: Close motor connection compartment
[1]
Cover
[2]
Screws for cover
[3]
O-ring
[4]
Cable gland
1.
Clean sealing faces of cover [1] and housing.
2.
Check whether O-ring [3] is in good condition, replace if damaged.
3.
Apply a thin film of non-acidic grease (e.g. petroleum jelly) to the O-ring and
insert it correctly.
4.
Fit cover [1] and fasten screws [2] evenly crosswise.
5.3.2.
Electrical connection (K/KR)
5.3.2.1. Terminal compartment: open
Figure 28: Open terminal compartment (for control contacts)
[1]
Cover
[2]
Screws
[3]
O-ring
[4]
Blanking plugs
[5]
Cable gland
[6]
Terminal frame (KR) – option
30
SAEx 25.1 – SAEx 40.1 / SAREx 25.1 – SAREx 30.1
Electrical connection
ACExC 01.2