Contact closure controlled page. All members of group 8 are paged. When contacts are
released paging is complete.
Feedbackwhen activated
‘AXP8ONG00<cr>
When deactivated
‘AXPGOFG00<cr>
MAXIMUM ALLOWABLE VOLUME
Allows you to set a maximum allowable volume level per room. The command is in the form
of MV## where ## is the allowable level 10 to 40.
EXAMPLE
‘SMV40R01<cr>
set maximum volume to 40 for room 1
Feedback
‘AXMV40R01<cr>
Feedback Request
‘GMV##R##
Feedback
‘AXMV##R##
ROOM TURN ON WITH LAST USED VOLUME, TONE, BALANCE
Room will turn on and use previous volume, bass, treble, stereo enhance, loudness contour
and balance settings.
EXAMPLE
‘SVPOFR01<cr>
use previous settings for tone,
balance and volume in room 1
Feedback
‘AXVPOFR01<cr>
Feedback Request
‘GVPOFR01<cr>
Feedback
‘AXVPONR01<cr> or
‘AXVPOFR01<cr>
ROOM TURN ON WITH VOLUME, TONE AND BALANCE IN PRESET 1
Room will turn on using volume, bass, treble, stereo enhance, loudness contour and balance
stored in volume preset 1, tone preset 1 and balance preset 1.
EXAMPLE
‘SVPONR01<cr>
use preset 1 for tone, balance and volume
Feedback
‘AXVPONR01<cr>
Feedback Request
‘GVPONR01<cr>
Feedback
‘AXVPONR01<cr> or
‘AXVPOFR01<cr>
VERSION REQUEST
This is a global command which will indicate the software version of each card. All audio
cards in the system will respond sequentially.
EXAMPLE Feedback Request
‘GVERSG00<cr>
Feedback
‘A0VERS1.4<cr>
card 0 has version 1.4 software
‘A1VERS1.4<cr>
card 1 has version 1.4 software