- 24 -
If you have a Suite-16 for 16 rooms that is switching composite video and you have a compo-
nent video switching matrix in a separate AVP-16 chassis, then you might opt to use the room
group address of 17-32 for the matrix switcher. As such, you could connect the Suite-16
audio video system running 16 zones with composite video (addressed for rooms 1-16) and
the 16 x 16 component video matrix Suite 16 (set to room address 17-32) on the same ADA
Bus network without conflict.
In the event, you have 17 or more rooms on a Suite-16 setup for audio and video switching,
you will need to communicate to the Suite-16 setup for component video switching, through a
separate com port. Here you could opt to run the matrix switcher on any of the two room
group addresses, as this switcher is not going to be connected directly to the Suite-16 audio
video system.
S-Video Switching
This configuration uses a
single AVP-16 chassis outfit-
ted with two V-16 modules.
One module is connected to
up to 16 S-Video “Y” outputs.
The second module connects
the “C” S-Video outputs. The
end result is a 16 x 16 S-Video switcher. Here the first card needs to be set to the 0 address
while the second unit is set to address 6. You can also uses addresses 1 and 7 respectively.
For 1200 baud systems, addresses 8 and 14 could be used or addresses 9 and 15.
Component Video Switching
This configuration uses a
single AVP-16 chassis outfit-
ted with three V-16 modules.
One module is connected to
up to 16 “Y” outputs. The
second module connects the
“Cr” component outputs. The
third card connects the “Cb” component outputs. The end result is a 16 x 16 component video
switcher. Here the first card needs to be set to the 0 address while the second and third cards
are set to address 6. You can also uses addresses 1 and 7 respectively. For 1200 baud
systems, addresses 8 and 14 could be used or addresses 9 and 15.
RGBHV Video Switching
This configuration uses a two AVP-16 chassis outfitted with three V-16 modules in the first
chassis and two in the second. One module is connected to up to 16 “R” outputs. The second
module connects the “G” video outputs. The third card connects the “B” video outputs. In the
second chassis, the first card is connect to the “H” video outputs and the second card is
connected to the “V” video outputs. The end result is a 16 x 16 component video switcher.
Here the first card needs to be set to the 0 address while the second, third, fourth, and fifth
cards are set to address 6. You can also uses addresses 1 and 7 respectively. For 1200 baud
systems, addresses 8 and 14 could be used or addresses 9 and 15. An RGBHV switcher is
a combination of the two diagrams above.
1/2 ASB
115V~
1/4 ASB
230V~
115V~/60Hz 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
230V
115V
1 Gnd
2 Fdbk
3 Cntrl
4 +V
ADA Busfi
Network Control I/O
Main
AC
Input
Switch
AC
(10A)
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L’Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
AVP-16 MR Controller
115 V
EXPANSION PORTS
VIDEO INPUTS
1
3
5
7
9
11
13
15
2
4
6
8
10
12
14
16
1
3
5
7
9
11
13
15
2
4
6
8
10
12
14
16
V-
16
V-16 Video I/O Module
Output Triggers
Input Triggers
+12VDC Outputs
Gnd
Out 8/16
Programmed Video
Input Triggers
5-24V AC DC
Gnd
(-)
1
(+)
2
(+)
3
(+)
4
(+)
Out 1/9
Out 2/10
Out 5/13
Out 6/14
Out 1-8
Out 9-16
Out 7/15
Out 4/12
Out 3/11
VIDEO INPUTS
1
3
5
7
9
11
13
15
2
4
6
8
10
12
14
16
1
3
5
7
9
11
13
15
2
4
6
8
10
12
14
16
V-
16
V-16 Video I/O Module
Output Triggers
Input Triggers
+12VDC Outputs
Gnd
Out 8/16
Programmed Video
Input Triggers
5-24V AC DC
Gnd
(-)
1
(+)
2
(+)
3
(+)
4
(+)
Out 1/9
Out 2/10
Out 5/13
Out 6/14
Out 1-8
Out 9-16
Out 7/15
Out 4/12
Out 3/11
1/2 ASB
115V~
1/4 ASB
230V~
115V~/60Hz 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
230V
115V
1 Gnd
2 Fdbk
3 Cntrl
4 +V
ADA Busfi
Network Control I/O
Main
AC
Input
Switch
AC
(10A)
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L’Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
AVP-16 MR Controller
115 V
EXPANSION PORTS
VIDEO INPUTS
1
3
5
7
9
11
13
15
2
4
6
8
10
12
14
16
1
3
5
7
9
11
13
15
2
4
6
8
10
12
14
16
V-
16
V-16 Video I/O Module
Output Triggers
Input Triggers
+12VDC Outputs
Gnd
Out 8/16
Programmed Video
Input Triggers
5-24V AC DC
Gnd
(-)
1
(+)
2
(+)
3
(+)
4
(+)
Out 1/9
Out 2/10
Out 5/13
Out 6/14
Out 1-8
Out 9-16
Out 7/15
Out 4/12
Out 3/11
VIDEO INPUTS
1
3
5
7
9
11
13
15
2
4
6
8
10
12
14
16
1
3
5
7
9
11
13
15
2
4
6
8
10
12
14
16
V-
16
V-16 Video I/O Module
Output Triggers
Input Triggers
+12VDC Outputs
Gnd
Out 8/16
Programmed Video
Input Triggers
5-24V AC DC
Gnd
(-)
1
(+)
2
(+)
3
(+)
4
(+)
Out 1/9
Out 2/10
Out 5/13
Out 6/14
Out 1-8
Out 9-16
Out 7/15
Out 4/12
Out 3/11
VIDEO INPUTS
1
3
5
7
9
11
13
15
2
4
6
8
10
12
14
16
1
3
5
7
9
11
13
15
2
4
6
8
10
12
14
16
V-
16
V-16 Video I/O Module
Output Triggers
Input Triggers
+12VDC Outputs
Gnd
Out 8/16
Programmed Video
Input Triggers
5-24V AC DC
Gnd
(-)
1
(+)
2
(+)
3
(+)
4
(+)
Out 1/9
Out 2/10
Out 5/13
Out 6/14
Out 1-8
Out 9-16
Out 7/15
Out 4/12
Out 3/11