MC-5000 Keypad Manual Setup
The EXTRA button is used to both permit the user to access other keypad functions while
permitting the installer to enter the keypad’s program mode.
To enter the program mode, press and hold the EXTRA button for 5 seconds. The display will
read the keypad’s version number followed by the enter code display:
CODE: _ _ _ _
Enter the ADA code number using the eight source buttons where the source button on the far
left refers to the number 1 and the source button on the far right refers to the number 8.
The following codes activate the associated menu functions.
After entering the code the display will confirm the setup mode selected.
For Code 1111, the display will read TEST KEYS. As sources are
selected, the selected source button will illuminate the active LED
color while the rest of the keypad LEDs will light up. Upon press the
source buttons, the following characters will be displayed on the twelve
character display. Pressing the Room Off button will turn off the source
LED’s. Pressing the Extra button will indicate EXTRA and then the
keypad will exit the Test Keys mode and return to normal operation.
IR Receiver On/Off Toggle
For Code 1112, the display will read IR ON or IR OFF depending on
the state of the IR. Re-entering this code will reverse the process.
Keypad Display Time Out - Bedroom Mode
For Code 1113, the display will read BLANKING ON or BLANKING
OFF, depending on the state of the readout display. Display will black
out after 5 seconds after receiving a feedback update.
Room Address
For Code 1116, the display will read the current room number:
SET ROOM # (where the # is the current room number)
To change the room number of the keypad, use the >> or <<. Room numbers will increment
between 1 and 99. Press EXTRA to exit the setup mode and the display will momentarily
read ROOM = # and then the display will return to normal operation.
BUTTON
DISPLAY
SOURCE 1
FM TUNER 1
SOURCE 2
FM TUNER 2
SOURCE 3
AM
SOURCE 4
CD PLAYER 1
SOURCE 5
CD PLAYER 2
SOURCE 6
DSS RECEIVER
SOURCE 7
DVD PLAYER
SOURCE 8
AUXILIARY
BASS UP
BASS UP
BASS DN
BASS DOWN
TREB UP
TREBLE UP
TREB DN
TREBLE DOWN
VOL UP
VOLUME UP
VOL DN
VOLUME DOWN
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
0
0
*
*
ENTER
ENTER
>>
FAST FORWARD
<<
REWIND
>
PLAY
<
REVERSE
STOP
STOP
PAUSE
PAUSE
CODE
MENU FUNCITON
DESCRIPTION
1111
TEST KEYS
DEMONSTRATION KEYPAD MODE
1112
IR ON/OFF TOGGLE
TURNS KEYPAD IR RECEIVER ON & OFF
1113
DISPLAY BLANK TOGGLE
WHEN THE SYSTEM IS OFF, THE KEYPAD DISPLAY BLANKS OUT AFTER A SHORT TIME.
1115
CLOCK SETUP
SET DATE AND TIME
1116
ROOM NUMBER
SETS ZONE KEYPAD ZONE NUMBER
1117
BAUD RATE 1200
SETS KEYPAD BAUD RATE TO 1200 BAUD
1118
BAUD RATE 19200
SETS KEYPAD BAUD RATE TO 19200 BAUD
1867
INSTALLER MODE
SETS KEYPAD INTO PROGRAM MODE