![Audio Design Associates Suite 16 System Design & Technical Documentation Download Page 68](http://html1.mh-extra.com/html/audio-design-associates/suite-16/suite-16_system-design-and-technical-documentation_3008134068.webp)
- 67 -
ROOM OFF
Shuts down the selected room. If it is the only room on in the system the response will be all
off.
EXAMPLE
‘SRMOFR01<cr>
turn off room 1
Feedback
‘AXRMOFR01<cr> or
room 1 is off
‘AXALOFG00
all off when last room turned off
Feedback Request
‘GRMOFR01<cr>
Feedback
‘AXRMOFR01<cr>
room 1 is off
Or
‘AXAD##R01<cr>
current input selected for room 1
Or
‘AXALOFG00<cr>
system is off
VOLUME UP
Advances the volume by 1 up to a maximum of 40 for a given room. If the volume has
reached 40 any additional commands will result in a volume level of 40. No function when
room is off. Feedback request allowed when room is off.
EXAMPLE
‘SVLUPR01<cr>
increment volume up by 1 in room 1
Feedback
‘AXV###R01<cr>
current volume set in room 1
Feedback Request
‘GVLUPR01<cr>
Feedback
‘AXV###R01<cr>
current volume set in room 1
VOLUME DOWN
Decrements the volume by 1 to a minimum of 0 for a given room. If the volume has reached
0 and additional commands will result in a volume level of 0. No function when room is off.
Feedback request allowed when room is off.
EXAMPLE
‘SVLDNR01<cr>
decrement volume by 1 in room 1
Feedback
‘AXV###R01<cr>
current volume set in room 1
Feedback Request
‘GVLDNR01<cr>
Feedback
‘AXV###R01<cr>
current volume set in room 1
VOLUME DIRECT
Allows you to go directly to a volume level for a given room. The function command is in the
form of V### where ###is a number from 000 to 040. No function when room is off. Feedback
request allowed when room is off.
EXAMPLE
‘SV040R01<cr>
set maximum volume in room 1
Feedback
‘AXV040R01<cr>
volume is set to maximum in room 1
Feedback Request
‘GV###R01<cr>
Feedback
‘AXV###R01
current volume value for room 1