CHAPTER 5: SYSTEM TAB
MDU Solutions
®
– UCrypt
®
Monitoring Server - Operation Manual
5-11
Table 5 .2a: VLAN Settings (See Figure 5-27)
Field
Confi gurable
Value
Interface Role
Dropdown Menu Management/Primary. Other options are available which should not be selected if you are setting
up a VLAN for remote management.
Base Address
Dropdown Menu Base address on which VLAN will operate.
VLAN Tag
Integer
802.1Q VLAN Tag identifi er to apply to the connection.
Use DHCP Client
Tick Box/Switch
Un-Ticked (Grayed out) for static IP address, ticked (checked) for DHCP.
DNS Server
IP Address
An external DNS server which can resolve URLs.
DNS Search Domain URL/IP Address The DNS search domain as required by your network.
NTP Server
URL/IP Address An accessible external NTP server to synchronize clock time on the Monitoring Server.
SNMP Access
Tick Box/Switch
Tick to allow SNMP messages on this interface. If enabled, the SNMP port will be enabled on
this interface.
Management GUI
Tick Box/Switch
Ticked to expose UI ports on this interface. Must be active on at least one interface.
ICMP Ping
Tick Box/Switch
Tick to enable ping response on this interface.
Support Access
Tick Box/Switch
If enabled, the support (ssh) port will be enabled on this interface; note it is strongly encouraged
to leave this enabled on at least one interface.
6. A VLAN is added to Interfaces with a name such as eth0.1 but is not yet activated, Figure 5-28.
7. Click
Apply Confi guration
button to activate changes.
8. If it is required to edit any existing interface, click the
Edit Icon
for the interface.
9. Created VLANs may be deleted by clicking the red
X
icon.
5 .3 Syslog Forwarding
This feature is required if a fi rewall exists between monitored UCrypt Servers and the Monitoring Server. In this case you may
specify that syslogs received from monitored UCrypt Servers are forwarded to the fi rewall or router IP address. The fi rewall or
router will then need to have UDP port 10514 forwarded to the Monitoring Server. The IP address specifi ed here will be used
to inform all monitored UCrypt Servers to send their syslog reports to this address instead of directly to the Monitoring Server.
Procedure
This procedure explains how to set up a syslog forwarding IP address.
1. Click the
System
tab if it is not already selected, Figure 5-29.
2. Click
Confi gure Syslog Forwarding IP
under Network Confi guration.
8
7
6
9
Figure 5-28: VLAN is Added to Interfaces
1
2
Figure 5-29: Open the System Tab