CHAPTER 5: SYSTEM TAB
MDU Solutions
®
– UCrypt
®
Monitoring Server - Operation Manual
5-5
Field
Confi gurable
Value
Support Access
Tick Box/Switch
If enabled, the support (ssh) port will be enabled on this interface; note it is strongly encouraged
to leave this enabled on at least one interface.
6. When saved, eth0 values are changed but not yet activated on the Server, Figure 5-8.
7. Click
Apply Confi guration
to activate the changes.
You will need to log in again using the new IP address in your browser if the Monitoring Server IP address was changed.
5 .2 .3 Monitor Network Performance
It is possible to view the aggregate network traffi c on any Ethernet interface occurring over a period of time.
Procedure
This procedure describes monitoring of the network performance histogram.
1. Click the
System
Tab, Figure 5-9.
2. Click
Confi gure
under
Network Confi guration
section.
3. Histogram of network data sent and received over each individual interface is updated every 10 seconds and shows
continuous history for as long as the window is open, Figure 5-10. The current data rate is also shown in Mbps or
kbps. The data rate histogram is for comparative purposes only and is not calibrated.
6
7
Figure 5-8: Changed Values Applied to eth0
1
2
Figure 5-9: Confi gure Network
3
Figure 5-10: Network Data Histogram