CHAPTER 1: ETHERNET MULTIPLEXER
9-2
VersAtive
®
Pro, DigiVu
®
II, DigiVu
®
II Micro – Operation Manual
5. From the
Interface
dropdown, select the physical output Ethernet port that the stream should appear on (Ports
available may differ between models and could include VLANs if previously configured).
NOTE:
The default management port is ETH0 and if Device is M-QAM equipped, the M-QAM is
using ETH1 so these two ports should not be used for streaming an Ethernet MUX.
6. Enter the TS (Transport Stream) ID number.
7. Tick
DVB SI Enable
only if required for the application, Figure 1-3.
•
If this box is ticked then enter Network ID, Name and Service Provider as well.
8. Once added, the MUX will be in the Tree View under the Device, Figure 1-4. No need to click Save.
9. If any changes are required, select the MUX in the Tree View then edit any parameters of the multiplex as required.
10. Click
Save
to apply any changes made.
Figure 1-3: Select PSIP for Multiplex
Figure 1-4: Multiplex Added to Device