www.atestgaz.pl
1. disconnect power supply from the control unit,
2. remove unit cover,
3. disconnect the front panel by unplugging the connector (see figure 2),
4. remove the discharged battery from the battery port or a burned fuse from the fuse seat (see
figure 2),
5. install a new battery or a fuse (for component types – see table 15),
6. connect and replace the unit cover,
7. connect power supply to the control unit.
8.5.2
Maintenance
Except for cleaning the external surface of unit housing, no special unit maintenance is required. Clean the
external unit housing with a non-abrasive cloth moistened with water and some soft detergent.
8.6
Utilization
This symbol on the product or its packaging indicates that this product
must not be disposed of with other household waste. Instead, it is user’s
responsibility to dispose of your waste equipment by handing it over to
a designated collection point for the recycling of waste electrical and
electronic equipment. The separate collection and recycling of your
waste equipment at the time of disposal will help conserve natural
resources and ensure that it is recycled in a manner that protects human
health and the environment. For more information about where you can
drop off your consumer waste equipment for recycling, please contact
your local city recycling office, waste collection company or the dealer
from whom you originally purchased the product. The product can be
also returned to its manufacturer.
9
Troubleshooting
9.1
Clock not set
In case the control unit signals “Clock not set” replace the battery and update the date and time settings
(see section 8.5.1).
p. 36|38