www.atestgaz.pl
6.1.6
Interface for executing operator commands (read / write)
Register
Name
Description
Type / range
43501
Command_Status
Current command execution status
Write – data ignored
Read – status, possible values include:
• 0 – inactive
• 1 – command in progress
• 2 – task completed successfully; this value is latched up for 5 s
from execution
• 3 – command execution not succeeded, incorrect command or
its parameters; this value is latched for 5 s from execution
U16
43502
Command_Code
Command code to be executed
Write – command code to be executed; Writing to this log initiates
command execution
Read – current command code value
For possible values – see description below
U16
43503
Command_Param
Command parameter
Read, Write – Command parameter
For possible values – see description below
U16
List of commands:
Command code
Description
1
Disable detector lock
Execution parameters – detector channel number to be cancelled, possible values: 1 – 20
7
Utilization
This symbol on the product or its packaging indicates that this product
must not be disposed of with other household waste. Instead, it is user’s
responsibility to dispose of your waste equipment by handing it over to
a designated collection point for the recycling of waste electrical and
electronic equipment. The separate collection and recycling of your waste
equipment at the time of disposal will help conserve natural resources and
ensure that it is recycled in a manner that protects human health and the
environment. For more information about where you can drop off your
consumer waste equipment for recycling, please contact your local city
recycling office, waste collection company or the dealer from whom you
originally purchased the product. The product can be also returned to its
manufacturer.
Atest Gaz
A. M. Pachole sp. j.
ul. Spokojna 3, 44-109 Gliwice, Poland
VAT No.: PL 9691433231
tel.: +48 32 238 87 94
fax: +48 32 234 92 71
e-mail: [email protected]
Appendix: PU-Z-062-ENG R06